Description My Buderus heater is not controlled via a room thermostat - in fact my RC35 is mounted to the boiler itself. The heating behaviour is controlled via outside temperature and via separate thermostats mounted to radiators. Sometimes I´m out of town, activate a lower temperature profile and disable water heating. For ease of use I use customised heating profiles. There are two custom profiles, that I´ve configured accordingly: When I´m present, I use /heatingCircuits/hc1/activeSwitchProgram/Eigen1 When away, I activate /heatingCircuits/hc1/activeSwitchProgram/Eigen2

Feature Request As I found no convenient solution for chaning the “activeSwitchProgram” via for example CURL, I´d love having an “input_select” way of switching the SwitchProgram. There are some different profiles, that can be picked:

Eigen1|Eigen2|Familie|Morgen|Abend|Vormittag|Nachmittag|Mittag|Single|Senioren

Most of them are predefined settings, but Eigen1 and Eigen2 can be customized.

Manual Operating Instructions Logamatic EMS describes profiles on page 32 to 34.

Lookup/Description for profiles:

Familie -> family
Purpose: Default program

Eigen1 -> costom1
Purpose: Custom profile 1

Eigen2 -> costom1
Purpose: Custom profile 2

Morgen -> early morning
Purpose: Early shift work

Abend -> evening
Purpose: Late shift work

Vormittag -> morning
Purpose: Part-time work, mornings only

Nachmittag -> afternoon
Purpose: Part-time work, afternoons only

Mittag -> midday
Purpose: At home at midday

Single -> single
Purpose: Single person

Senioren -> senior citizens
Purpose: Senior citizens

Closing words Hope, I described it comprehensible 😃.

Thanks and regards,

Jakob

Issue Analytics

  • State:closed
  • Created 3 years ago
  • Comments:15

github_iconTop GitHub Comments

1reaction
pszafercommented, Nov 29, 2020

in Polish they made 2 very sophisticated values: [ “1”, “2” ] 😉

0reactions
pszafercommented, Mar 1, 2021

cool, HVAC mode was first in HA UI and it was designed for operation mode so it was pretty natural choice

Read more comments on GitHub >

github_iconTop Results From Across the Web

Control your Android device with Switch Access
Switch Access lets you interact with your Android device using one or more switches instead of the touchscreen. Switch Access can be helpful...
Read more >
Abort integration via HA 0.100.3 · Issue #11 - GitHub
Hello, Thank you for your work. Trying to integrate your component, but have Aborted for version 0.4.2 and 0.5.1 Latest release (0.3 alpha) ......
Read more >
Binding Request : Buderus web gateway - openHAB Community
As first the device has to go online. In a second step you have to search for the things (services) and link them...
Read more >
Buderus KM200 api - Logic Machine Forum
Control of Buderus boilers using a Logamatic web KM200 module. -- Logamatic web KM50, KM100, ... /heatingCircuits/hc1/activeSwitchProgram
Read more >
Test Adapter HeatingControl v2.9.x - ioBroker Forum
Ich habe heating control V1.2 aus Github am laufen. ... instance system.adapter.feiertage.0 terminated with code 0 (NO_ERROR).
Read more >

github_iconTop Related Medium Post

No results found

github_iconTop Related StackOverflow Question

No results found

github_iconTroubleshoot Live Code

Lightrun enables developers to add logs, metrics and snapshots to live code - no restarts or redeploys required.
Start Free

github_iconTop Related Reddit Thread

No results found

github_iconTop Related Hackernoon Post

No results found

github_iconTop Related Tweet

No results found

github_iconTop Related Dev.to Post

No results found

github_iconTop Related Hashnode Post

No results found