I followed the guide on heise. I already got the device info:

====================================================== Getting Info from IoT-device VTRUST-FLASH 1.0 © VTRUST GMBH https://www.vtrust.de/35c3/

READ FLASH: http://10.42.42.42/get?read=HEX-ADDRESS ChipID: xxxxxx MAC: YY:YY:YY:XX:XX:XX SdkVersion: 1.5.3(aec24ac9) BootVersion: 4 BootMode: 1 FlashMode: 1M DOUT @ 40MHz FlashChipId: 144051 FlashChipRealSize: 1048576 FlashChipSize: 1048576 FlashChipMode: 3 system_upgrade_userbin_check: user2 0x81000

======================================================

After this I try to get tasmota:

curl http://10.42.42.42/flash3

And got the following response:

Device should flash http://10.42.42.1/files/user2.bin and restart

Tasmota never started. Instead I see a SSID named ESP_XXXXXX. Connecting to it gives me the IP 192.168.4.2 and a default gateway on 192.168.4.1. I can ping the device on that address, but it didn’t reply to http requests.

Because user2.bin is linked to esp8266-ota-flash-convert.ino-0x81000.bin: What is it? Why the command don’t install sonoff-minimal.bin?

Do anybody have some hints for me, what I did wrong or some advises how I can continue without opening the device? Maybe this is also connected to issue #2?!

Issue Analytics

  • State:closed
  • Created 5 years ago
  • Comments:20

github_iconTop GitHub Comments

1reaction
modellbobbycommented, Feb 13, 2019

Hi Guys,

i have lot of TECKIN EU SP22 and i followed the procedure. I come till the SonoffXXXX AP turns on and then I only can setup my WIFI credentials on that but cannot set the model. Is this by design? All my TECKINS dissapear afterwards and seem to not connect to the net and are not reachable.

Please help!

1reaction
HeinrichLohsecommented, Jan 26, 2019

@baxerus, thanks for motivating me to just plug it in again. Surprisingly the sonoff-xxxx network showed up immediately. Now everythink works as expected.

Read more comments on GitHub >

github_iconTop Results From Across the Web

Stuck on flashing minimal build off tasmota on TECKIN SP22
Tasmota never started. Instead I see a SSID named ESP_XXXXXX . Connecting to it gives me the IP 192.168.4.2 and a default gateway...
Read more >
Tuya Convert 2.0 - Flashing a switch blocked firmware switch
Showing the new changes to the Tuya Convert to flash those updated devices with blocked firmware! Update them while you can as the...
Read more >
I bought last week a Teckin SP22 which is a Tuya OEM smart ...
I have no idea how to flash this version as I understood you need a SDK to do so. Is anyone aware of...
Read more >
Ghost in the Shell - Fixing your MQTT issues
First flashing the latest minimal build and then flashing the full firmware build ... Teckin SP22 running the latest Tasmota firmware.
Read more >
Teckin SP22 - Tasmota
There are at least two Versions of the SP22 out. An old one with a TYWE2S WiFi module and ESP... chip. This version...
Read more >

github_iconTop Related Medium Post

No results found

github_iconTop Related StackOverflow Question

No results found

github_iconTroubleshoot Live Code

Lightrun enables developers to add logs, metrics and snapshots to live code - no restarts or redeploys required.
Start Free

github_iconTop Related Reddit Thread

No results found

github_iconTop Related Hackernoon Post

No results found

github_iconTop Related Tweet

No results found

github_iconTop Related Dev.to Post

No results found

github_iconTop Related Hashnode Post

No results found