AC doesn't connect.
See original GitHub issueVersions (版本信息)
- midea_ac custom component installed with HACS, at version (commit) 718aba1
- AC: “sysplit wall smart 12 v2 evo hp q”. Works with NetHome Plus Android application
- Wi-Fi module: probably SK-105
- Home Assistant version: core-2022.2.7
- Home Assistant OS version: 7.4
- Supervisor version: supervisor-2022.01.1
- Midea msmart version: msmart-0.2.0-py3-none-any
- Platform: Raspberry Pi
Describe the bug (描述一下问题) The issue very similar to https://github.com/mac-zhou/midea-ac-py/issues/121 . midea-discover returns different token and key at each run: First run:
c:\Python310\Scripts>midea-discover
INFO:msmart.cli:msmart version: 0.2.0 Currently only supports ac devices.
ERROR:msmart.security:authentication failed
INFO:msmart.lan:Got TCP key for 192.168.0.107:51577 -> 192.168.0.104:6444 retries: 0 time: 0.32 e994220f1b2281c899e02cbcfc61c844a2149ff05fc10b9f0224a88301590029
INFO:msmart.cli:*** Found a device: ←[94m←[1m{'type': 'ac', 'support': True, 'version': 3, 'ip': '192.168.0.104', 'id': 35184372114367, 'port': 6444, 'token': '9D0C185355F5F1D4EFABDF9739D0AA74EF98DBE0906700933F36DC98082F6D61F7BAFB21CE19C54FE9E16C7383A7838BB33EA27BEE0B333B50D94FF24FC4FB90', 'key': '0D6C677656294787A73F6CF29607890971585DBD265149D3A761EBCF7172C365', 'ssid': 'net_ac_093C'} ←[0m
Second run:
c:\Python310\Scripts>midea-discover
INFO:msmart.cli:msmart version: 0.2.0 Currently only supports ac devices.
ERROR:msmart.security:authentication failed
INFO:msmart.lan:Got TCP key for 192.168.0.107:51586 -> 192.168.0.104:6444 retries: 0 time: 0.37 e420e1174300eaa7cce4f002004e2aad198ca2341135e68a43e0da38912a3185
INFO:msmart.cli:*** Found a device: ←[94m←[1m{'type': 'ac', 'support': True, 'version': 3, 'ip': '192.168.0.104', 'id': 35184372114367, 'port': 6444, 'token': '507AA10FD3CD08B5351520B8360C49B5AEC09C9EA10123FF45F771C96892BF3125B20A1FA70C05E208E0952D7D74D9574CE2CC0809B6F7FAE0BC613099A213AB', 'key': '40E2C85D7D8B41CCBBA25A683A2C01C78748095E29234DE0A9A5715228069AEF', 'ssid': 'net_ac_093C'} ←[0m
With configuration
climate:
- platform: midea_ac
host: 192.168.1.104
id: 35184372114367
# v3 need token and k1(key)
token: 507AA10FD3CD08B5351520B8360C49B5AEC09C9EA10123FF45F771C96892BF3125B20A1FA70C05E208E0952D7D74D9574CE2CC0809B6F7FAE0BC613099A213AB
k1: 40E2C85D7D8B41CCBBA25A683A2C01C78748095E29234DE0A9A5715228069AEF
HA can’t connect to AC, with errors in logs:
2022-02-21 01:41:32 ERROR (MainThread) [homeassistant.components.automation.update_input_select_fan_mode] Update Input Select Fan Mode: Error executing script. Invalid data for call_service at pos 1: string value is None for dictionary value @ data['option']
2022-02-21 01:41:32 ERROR (MainThread) [homeassistant.components.automation.update_input_select_fan_mode] Error while executing automation automation.update_input_select_fan_mode: string value is None for dictionary value @ data['option']
2022-02-21 01:41:35 ERROR (SyncWorker_3) [msmart.lan] Connect Error: 192.168.1.104:6444 timed out
2022-02-21 01:41:35 ERROR (SyncWorker_3) [msmart.lan] Sokcet is None: 192.168.1.104:6444
2022-02-21 01:41:35 ERROR (SyncWorker_3) [msmart.security] unexpected data length
2022-02-21 01:41:35 ERROR (MainThread) [homeassistant.helpers.entity] Update for climate.midea_ac_35184372114367 fails
Traceback (most recent call last):
File "/usr/src/homeassistant/homeassistant/helpers/entity.py", line 521, in async_update_ha_state
await self.async_device_update()
File "/usr/src/homeassistant/homeassistant/helpers/entity.py", line 725, in async_device_update
raise exc
File "/config/custom_components/midea_ac/climate.py", line 133, in async_update
await self.hass.async_add_executor_job(self._device.refresh)
File "/usr/local/lib/python3.9/concurrent/futures/thread.py", line 52, in run
result = self.fn(*self.args, **self.kwargs)
File "/usr/local/lib/python3.9/site-packages/msmart/device.py", line 198, in refresh
self._send_cmd(cmd)
File "/usr/local/lib/python3.9/site-packages/msmart/device.py", line 208, in _send_cmd
responses = self._lan_service.appliance_transparent_send_8370(data)
File "/usr/local/lib/python3.9/site-packages/msmart/lan.py", line 136, in appliance_transparent_send_8370
data = self.security.encode_8370(data, msgtype)
File "/usr/local/lib/python3.9/site-packages/msmart/security.py", line 120, in encode_8370
data = self.aes_cbc_encrypt(data, self._tcp_key) + sign
File "/usr/local/lib/python3.9/site-packages/msmart/security.py", line 57, in aes_cbc_encrypt
return AES.new(key, AES.MODE_CBC, iv=self.iv).encrypt(raw)
File "/usr/local/lib/python3.9/site-packages/Cryptodome/Cipher/AES.py", line 232, in new
return _create_cipher(sys.modules[__name__], key, mode, *args, **kwargs)
File "/usr/local/lib/python3.9/site-packages/Cryptodome/Cipher/__init__.py", line 79, in _create_cipher
return modes[mode](factory, **kwargs)
File "/usr/local/lib/python3.9/site-packages/Cryptodome/Cipher/_mode_cbc.py", line 274, in _create_cbc_cipher
cipher_state = factory._create_base_cipher(kwargs)
File "/usr/local/lib/python3.9/site-packages/Cryptodome/Cipher/AES.py", line 92, in _create_base_cipher
if len(key) not in key_size:
TypeError: object of type 'NoneType' has no len()
2022-02-21 01:41:50 ERROR (SyncWorker_0) [msmart.lan] Connect Error: 192.168.1.104:6444 timed out
2022-02-21 01:41:50 ERROR (SyncWorker_0) [msmart.lan] Sokcet is None: 192.168.1.104:6444
2022-02-21 01:41:50 ERROR (SyncWorker_0) [msmart.security] unexpected data length
2022-02-21 01:41:50 ERROR (MainThread) [homeassistant.helpers.entity] Update for climate.midea_ac_35184372114367 fails
Traceback (most recent call last):
File "/usr/src/homeassistant/homeassistant/helpers/entity.py", line 521, in async_update_ha_state
await self.async_device_update()
File "/usr/src/homeassistant/homeassistant/helpers/entity.py", line 725, in async_device_update
raise exc
File "/config/custom_components/midea_ac/climate.py", line 133, in async_update
await self.hass.async_add_executor_job(self._device.refresh)
File "/usr/local/lib/python3.9/concurrent/futures/thread.py", line 52, in run
result = self.fn(*self.args, **self.kwargs)
File "/usr/local/lib/python3.9/site-packages/msmart/device.py", line 198, in refresh
self._send_cmd(cmd)
File "/usr/local/lib/python3.9/site-packages/msmart/device.py", line 208, in _send_cmd
responses = self._lan_service.appliance_transparent_send_8370(data)
File "/usr/local/lib/python3.9/site-packages/msmart/lan.py", line 136, in appliance_transparent_send_8370
data = self.security.encode_8370(data, msgtype)
File "/usr/local/lib/python3.9/site-packages/msmart/security.py", line 120, in encode_8370
data = self.aes_cbc_encrypt(data, self._tcp_key) + sign
File "/usr/local/lib/python3.9/site-packages/msmart/security.py", line 57, in aes_cbc_encrypt
return AES.new(key, AES.MODE_CBC, iv=self.iv).encrypt(raw)
File "/usr/local/lib/python3.9/site-packages/Cryptodome/Cipher/AES.py", line 232, in new
return _create_cipher(sys.modules[__name__], key, mode, *args, **kwargs)
File "/usr/local/lib/python3.9/site-packages/Cryptodome/Cipher/__init__.py", line 79, in _create_cipher
return modes[mode](factory, **kwargs)
File "/usr/local/lib/python3.9/site-packages/Cryptodome/Cipher/_mode_cbc.py", line 274, in _create_cbc_cipher
cipher_state = factory._create_base_cipher(kwargs)
File "/usr/local/lib/python3.9/site-packages/Cryptodome/Cipher/AES.py", line 92, in _create_base_cipher
if len(key) not in key_size:
TypeError: object of type 'NoneType' has no len()
Here is log file attached home-assistant.zip
When I scan opened ports of 192.168.1.104 with Network Scanner (Android app), I see one opened port 6444/tcp (unknown).
When I trying to connect with telnet
telnet 192.168.1.104 6444
Connect failed:
C:\Users\art>telnet 192.168.1.104 6444
Connecting To 192.168.1.104...Could not open connection to the host, on port 6444: Connect failed
So, AC has opened port, that can’t be accessed with telnet and, probably, HA too (ERROR (SyncWorker_3) [msmart.lan] Connect Error: 192.168.1.104:6444 timed out).
Any ideas, my friends?..
Issue Analytics
- State:
- Created 2 years ago
- Comments:15 (4 by maintainers)
Top Results From Across the Web
10 Reasons Your Air Conditioner Isn't Working
10 Reasons Your Air Conditioner Isn't Working · 1. Your thermostat batteries are dead. · 2. The indoor disconnect switch is off. ·...
Read more >Why is My AC Not Turning On? How to Fix? [With Pictures]
If there is no electricity connected to your HVAC system, your AC unit will not turn on. Pay attention that the HVAC furnace...
Read more >Why is My Air Conditioner Not Working? 10 Possible Reasons
One of the simplest things to do is check your thermostat setting. If your thermostat is set incorrectly then your AC isn't going...
Read more >Air Conditioner Not Working? Problems and Solutions
If your AC indoor fan isn't working, first check to make sure a breaker hasn't been tripped. If all is OK, check your...
Read more >The 9 Most Common Reasons Why Your AC Won't Turn On
1. Thermostat Issues. Your thermostat is your way of communicating with your air conditioner. · 2. Circuit Breaker Tripped · 3. Condenser Unit ......
Read more >Top Related Medium Post
No results found
Top Related StackOverflow Question
No results found
Troubleshoot Live Code
Lightrun enables developers to add logs, metrics and snapshots to live code - no restarts or redeploys required.
Start FreeTop Related Reddit Thread
No results found
Top Related Hackernoon Post
No results found
Top Related Tweet
No results found
Top Related Dev.to Post
No results found
Top Related Hashnode Post
No results found
Top GitHub Comments
I guess you have solved it? 😄