[regoheatpump] Husdata Thing toggles between ONLINE and OFFLINE
See original GitHub issueExpected Behavior
When using the RegoHeatPump binding with a USB connected Husdata H14 interface on a Thermia Diplomat Optimum G2 heatpump it is expected to have the serialHusdata Thing constantly ONLINE.
Current Behavior
The serialHusdata Thing constantly toggles between ONLINE and OFFLINE as seen in the event.log:
2018-12-03 21:20:38.816 [hingStatusInfoChangedEvent] - 'regoheatpump:serialHusdata:ivtSerial' changed from ONLINE to OFFLINE
2018-12-03 21:20:48.158 [hingStatusInfoChangedEvent] - 'regoheatpump:serialHusdata:ivtSerial' changed from OFFLINE to ONLINE
2018-12-03 21:20:48.171 [vent.ItemStateChangedEvent] - Heatpump_SensorValues_RadiatorReturn changed from 34.0 to 33.0
2018-12-03 21:20:48.565 [hingStatusInfoChangedEvent] - 'regoheatpump:serialHusdata:ivtSerial' changed from ONLINE to OFFLINE
2018-12-03 21:20:53.165 [hingStatusInfoChangedEvent] - 'regoheatpump:serialHusdata:ivtSerial' changed from OFFLINE to ONLINE
2018-12-03 21:20:53.613 [hingStatusInfoChangedEvent] - 'regoheatpump:serialHusdata:ivtSerial' changed from ONLINE to OFFLINE
2018-12-03 21:20:56.645 [hingStatusInfoChangedEvent] - 'regoheatpump:serialHusdata:ivtSerial' changed from OFFLINE to ONLINE
2018-12-03 21:20:56.995 [hingStatusInfoChangedEvent] - 'regoheatpump:serialHusdata:ivtSerial' changed from ONLINE to OFFLINE
The openhab.log with DEBUG on org.openhab.binding.regoheatpump
2018-12-03 21:20:40.098 [DEBUG] [ternal.protocol.SerialRegoConnection] - Connected to /dev/ttyUSB0
2018-12-03 21:20:40.101 [DEBUG] [.regoheatpump.handler.HusdataHandler] - Requesting read and dump of real-time registers.
2018-12-03 21:20:40.204 [WARN ] [.regoheatpump.handler.HusdataHandler] - Processing request failed
java.io.IOException: Underlying input stream returned zero bytes
at sun.nio.cs.StreamDecoder.readBytes(StreamDecoder.java:288) ~[?:?]
at sun.nio.cs.StreamDecoder.implRead(StreamDecoder.java:326) ~[?:?]
at sun.nio.cs.StreamDecoder.read(StreamDecoder.java:178) ~[?:?]
at java.io.InputStreamReader.read(InputStreamReader.java:184) ~[?:?]
at java.io.BufferedReader.fill(BufferedReader.java:161) ~[?:?]
at java.io.BufferedReader.readLine(BufferedReader.java:324) ~[?:?]
at java.io.BufferedReader.readLine(BufferedReader.java:389) ~[?:?]
at org.openhab.binding.regoheatpump.handler.HusdataHandler.handleDataFromHusdataInterface(HusdataHandler.java:112) ~[?:?]
at java.util.concurrent.Executors$RunnableAdapter.call(Executors.java:511) [?:?]
at java.util.concurrent.FutureTask.runAndReset(FutureTask.java:308) [?:?]
at java.util.concurrent.ScheduledThreadPoolExecutor$ScheduledFutureTask.access$301(ScheduledThreadPoolExecutor.java:180) [?:?]
at java.util.concurrent.ScheduledThreadPoolExecutor$ScheduledFutureTask.run(ScheduledThreadPoolExecutor.java:294) [?:?]
at java.util.concurrent.ThreadPoolExecutor.runWorker(ThreadPoolExecutor.java:1149) [?:?]
at java.util.concurrent.ThreadPoolExecutor$Worker.run(ThreadPoolExecutor.java:624) [?:?]
at java.lang.Thread.run(Thread.java:748) [?:?]
2018-12-03 21:20:41.718 [DEBUG] [ternal.protocol.SerialRegoConnection] - Connected to /dev/ttyUSB0
2018-12-03 21:20:41.721 [DEBUG] [.regoheatpump.handler.HusdataHandler] - Requesting read and dump of real-time registers.
2018-12-03 21:20:41.727 [DEBUG] [.regoheatpump.handler.HusdataHandler] - Got 'XR'
2018-12-03 21:20:41.730 [DEBUG] [.regoheatpump.handler.HusdataHandler] - Unexpected length for 'XR'
2018-12-03 21:20:41.833 [WARN ] [.regoheatpump.handler.HusdataHandler] - Processing request failed
java.io.IOException: Underlying input stream returned zero bytes
<same-stacktrace-deleted>
2018-12-03 21:20:43.338 [DEBUG] [ternal.protocol.SerialRegoConnection] - Connected to /dev/ttyUSB0
2018-12-03 21:20:43.341 [DEBUG] [.regoheatpump.handler.HusdataHandler] - Requesting read and dump of real-time registers.
2018-12-03 21:20:43.349 [DEBUG] [.regoheatpump.handler.HusdataHandler] - Got 'XR'
2018-12-03 21:20:43.352 [DEBUG] [.regoheatpump.handler.HusdataHandler] - Unexpected length for 'XR'
2018-12-03 21:20:43.455 [WARN ] [.regoheatpump.handler.HusdataHandler] - Processing request failed
java.io.IOException: Underlying input stream returned zero bytes
<same-stacktrace-deleted>
2018-12-03 21:20:44.928 [DEBUG] [ternal.protocol.SerialRegoConnection] - Connected to /dev/ttyUSB0
2018-12-03 21:20:44.931 [DEBUG] [.regoheatpump.handler.HusdataHandler] - Requesting read and dump of real-time registers.
2018-12-03 21:20:44.938 [DEBUG] [.regoheatpump.handler.HusdataHandler] - Got 'XR'
2018-12-03 21:20:44.942 [DEBUG] [.regoheatpump.handler.HusdataHandler] - Unexpected length for 'XR'
2018-12-03 21:20:45.045 [WARN ] [.regoheatpump.handler.HusdataHandler] - Processing request failed
java.io.IOException: Underlying input stream returned zero bytes
<same-stacktrace-deleted>
2018-12-03 21:20:46.488 [DEBUG] [ternal.protocol.SerialRegoConnection] - Connected to /dev/ttyUSB0
2018-12-03 21:20:46.490 [DEBUG] [.regoheatpump.handler.HusdataHandler] - Requesting read and dump of real-time registers.
2018-12-03 21:20:46.497 [DEBUG] [.regoheatpump.handler.HusdataHandler] - Got 'XR'
2018-12-03 21:20:46.499 [DEBUG] [.regoheatpump.handler.HusdataHandler] - Unexpected length for 'XR'
2018-12-03 21:20:46.602 [WARN ] [.regoheatpump.handler.HusdataHandler] - Processing request failed
java.io.IOException: Underlying input stream returned zero bytes
<same-stacktrace-deleted>
2018-12-03 21:20:48.038 [DEBUG] [ternal.protocol.SerialRegoConnection] - Connected to /dev/ttyUSB0
2018-12-03 21:20:48.041 [DEBUG] [.regoheatpump.handler.HusdataHandler] - Requesting read and dump of real-time registers.
2018-12-03 21:20:48.048 [DEBUG] [.regoheatpump.handler.HusdataHandler] - Got 'XR'
2018-12-03 21:20:48.051 [DEBUG] [.regoheatpump.handler.HusdataHandler] - Unexpected length for 'XR'
2018-12-03 21:20:48.143 [DEBUG] [.regoheatpump.handler.HusdataHandler] - Got 'XR0001014A'
2018-12-03 21:20:48.146 [DEBUG] [.regoheatpump.handler.HusdataHandler] - dataType = 0, register = 1, value = 330
2018-12-03 21:20:48.252 [DEBUG] [.regoheatpump.handler.HusdataHandler] - Got 'XR6F561046'
2018-12-03 21:20:48.255 [DEBUG] [.regoheatpump.handler.HusdataHandler] - dataType = 6, register = 3926, value = 4166
2018-12-03 21:20:48.261 [DEBUG] [.regoheatpump.handler.HusdataHandler] - Unsupported register 3926.
2018-12-03 21:20:48.364 [WARN ] [.regoheatpump.handler.HusdataHandler] - Processing request failed
java.io.IOException: Underlying input stream returned zero bytes
<same-stacktrace-deleted>
2018-12-03 21:20:49.848 [DEBUG] [ternal.protocol.SerialRegoConnection] - Connected to /dev/ttyUSB0
2018-12-03 21:20:49.852 [DEBUG] [.regoheatpump.handler.HusdataHandler] - Requesting read and dump of real-time registers.
2018-12-03 21:20:49.858 [DEBUG] [.regoheatpump.handler.HusdataHandler] - Got 'XR'
2018-12-03 21:20:49.861 [DEBUG] [.regoheatpump.handler.HusdataHandler] - Unexpected length for 'XR'
2018-12-03 21:20:49.964 [WARN ] [.regoheatpump.handler.HusdataHandler] - Processing request failed
java.io.IOException: Underlying input stream returned zero bytes
<same-stacktrace-deleted>
2018-12-03 21:20:51.408 [DEBUG] [ternal.protocol.SerialRegoConnection] - Connected to /dev/ttyUSB0
2018-12-03 21:20:51.410 [DEBUG] [.regoheatpump.handler.HusdataHandler] - Requesting read and dump of real-time registers.
2018-12-03 21:20:51.417 [DEBUG] [.regoheatpump.handler.HusdataHandler] - Got 'XR'
2018-12-03 21:20:51.419 [DEBUG] [.regoheatpump.handler.HusdataHandler] - Unexpected length for 'XR'
2018-12-03 21:20:51.527 [WARN ] [.regoheatpump.handler.HusdataHandler] - Processing request failed
java.io.IOException: Underlying input stream returned zero bytes
<same-stacktrace-deleted>
2018-12-03 21:20:53.058 [DEBUG] [ternal.protocol.SerialRegoConnection] - Connected to /dev/ttyUSB0
2018-12-03 21:20:53.060 [DEBUG] [.regoheatpump.handler.HusdataHandler] - Requesting read and dump of real-time registers.
2018-12-03 21:20:53.067 [DEBUG] [.regoheatpump.handler.HusdataHandler] - Got 'XR'
2018-12-03 21:20:53.069 [DEBUG] [.regoheatpump.handler.HusdataHandler] - Unexpected length for 'XR'
2018-12-03 21:20:53.155 [DEBUG] [.regoheatpump.handler.HusdataHandler] - Got 'XR00060050'
2018-12-03 21:20:53.158 [DEBUG] [.regoheatpump.handler.HusdataHandler] - dataType = 0, register = 6, value = 80
2018-12-03 21:20:53.256 [DEBUG] [.regoheatpump.handler.HusdataHandler] - Got 'XR6F561046'
2018-12-03 21:20:53.258 [DEBUG] [.regoheatpump.handler.HusdataHandler] - dataType = 6, register = 3926, value = 4166
2018-12-03 21:20:53.262 [DEBUG] [.regoheatpump.handler.HusdataHandler] - Unsupported register 3926.
2018-12-03 21:20:53.365 [WARN ] [.regoheatpump.handler.HusdataHandler] - Processing request failed
java.io.IOException: Underlying input stream returned zero bytes
<same-stacktrace-deleted>
2018-12-03 21:20:54.898 [DEBUG] [ternal.protocol.SerialRegoConnection] - Connected to /dev/ttyUSB0
2018-12-03 21:20:54.900 [DEBUG] [.regoheatpump.handler.HusdataHandler] - Requesting read and dump of real-time registers.
2018-12-03 21:20:54.907 [DEBUG] [.regoheatpump.handler.HusdataHandler] - Got 'XR'
2018-12-03 21:20:54.912 [DEBUG] [.regoheatpump.handler.HusdataHandler] - Unexpected length for 'XR'
2018-12-03 21:20:55.016 [WARN ] [.regoheatpump.handler.HusdataHandler] - Processing request failed
java.io.IOException: Underlying input stream returned zero bytes
<same-stacktrace-deleted>
2018-12-03 21:20:56.558 [DEBUG] [ternal.protocol.SerialRegoConnection] - Connected to /dev/ttyUSB0
I suspect that when the input on the serial connection is exhausted the conenction is closed, even though there will be more data to read shortly.
The config is as follows:
Hardware: Heatpump - Husdata H14 - Raspberry Openhab2 2.3.0 binding-regoheatpump-2.3.0
the.things
Thing regoheatpump:serialHusdata:ivtSerial "Heatpump" @ "Trappen" [ portName="/dev/ttyUSB0" ]
the.items
Number Heatpump_SensorValues_RadiatorReturn "Returledning" <temperature> {channel="regoheatpump:serialHusdata:ivtSerial:sensorValues#radiatorReturn", mqtt=">[mosquitto:home/heatpump/sensor/radiatorreturn:state:*:default]"}
Number Heatpump_SensorValues_RadiatorForward "Framledning" <temperature> {channel="regoheatpump:serialHusdata:ivtSerial:sensorValues#radiatorForward", mqtt=">[mosquitto:home/heatpump/sensor/radiatorforward:state:*:default]"}
<and so on>
Possible Solution
If it would be possible to leave the serial connection open and the Thing ONLINE the eventlog would not be spammed and the Thing status would match the expected.
Also, the data is volunteered by the interface as the registers change. The “XR” command does not need to be sent repeatedly. Even with Openhab2 service stopped the data continue to flow (checked with screen /dev/ttyUSB0):
XR00090258
XR8105FA60
XR310902D0
XR8105FA88
XR8105FAB0
XR00120334
XR8105FAD8
XR8105FB00
XR0001019A
XR0012033E
XR310902C6
XR8105FB28
XR310902BC
XR310902A8
XR000201CC
XR8105FB50
XR3109029E
XR00120348
XR8105FB82
XR8105FBB4
However, the data is often coming 2-3 lines at a time. This is what triggers the Unexpected length for 'XR' debug message.
Steps to Reproduce (for Bugs)
- Connect hardware according to described setup
- Match software versions
- Just watch the logs
Context
This issue generates unnecessary log items and indicates that the Husdata interface is offline even if it is not.
Your Environment
- Version used: 2.3.0
- Environment name and version: OpenJDK Runtime Environment (Zulu Embedded 8.25.0.76-linux-aarch32hf) (build 1.8.0_152-b76)
- Operating System and version: Raspbian GNU/Linux 9 (stretch)
Issue Analytics
- State:
- Created 5 years ago
- Comments:31 (17 by maintainers)

Top Related StackOverflow Question
@crnjan - I sendt you an email now with some details 😃
tail -f /var/log/openhab2/openhab.log /var/log/openhab2/events.log
Filter 2019-01-20 19:16:41.107 [.ItemChannelLinkAddedEvent] - Link ‘Varmepumpe_SensorValues_Compressor-regoheatpump:serialHusdata:12eb66d3:sensorValues#compressor’ has been added.
2019-01-20 19:16:41.114 [.ItemChannelLinkAddedEvent] - Link ‘Varmepumpe_ControlData_RadiatorReturnTarget-regoheatpump:serialHusdata:5a58bd01:controlData#radiatorReturnTarget’ has been added.
2019-01-20 19:16:41.120 [.ItemChannelLinkAddedEvent] - Link ‘Varmepumpe_SensorValues_HotWater-regoheatpump:serialHusdata:5a58bd01:sensorValues#hotWater’ has been added.
2019-01-20 19:16:41.123 [.ItemChannelLinkAddedEvent] - Link ‘Varmepumpe_ControlData_AdditionalHeatPower-regoheatpump:serialHusdata:5a58bd01:controlData#addHeatPowerPercent’ has been added.
2019-01-20 19:16:41.132 [.ItemChannelLinkAddedEvent] - Link ‘Varmepumpe_Settings_HeatCurve-regoheatpump:serialHusdata:cecec0a8:settings#heatCurve’ has been added.
2019-01-20 19:16:41.140 [.ItemChannelLinkAddedEvent] - Link ‘Varmepumpe_SensorValues_HeatFluidOut-regoheatpump:serialHusdata:5a58bd01:sensorValues#heatFluidOut’ has been added.
2019-01-20 19:16:41.146 [.ItemChannelLinkAddedEvent] - Link ‘AdditionalHeat3kW-regoheatpump:serialHusdata:8d9e73fd:deviceValues#additionalHeat3kW’ has been added.
2019-01-20 19:16:41.156 [.ItemChannelLinkAddedEvent] - Link ‘HusdataInterface_SensorValues_ColdFluidOut-regoheatpump:serialHusdata:8f170952:sensorValues#coldFluidOut’ has been added.
2019-01-20 19:16:41.162 [.ItemChannelLinkAddedEvent] - Link ‘Varmepumpe_ControlData_CompressorSpeed-regoheatpump:serialHusdata:cecec0a8:controlData#compressorSpeed’ has been added.
2019-01-20 19:16:41.172 [.ItemChannelLinkAddedEvent] - Link ‘Varmepumpe_Settings_IndoorTarget-regoheatpump:serialHusdata:cecec0a8:settings#indoorTempSetting’ has been added.
2019-01-20 19:16:41.176 [.ItemChannelLinkAddedEvent] - Link ‘VPVerksted_SensorValues_Outdoor-regoheatpump:serialHusdata:4f00fe28:sensorValues#outdoor’ has been added.
2019-01-20 19:16:45.450 [hingStatusInfoChangedEvent] - ‘bosesoundtouch:30:506583CE0123’ changed from UNINITIALIZED to INITIALIZING
2019-01-20 19:16:46.665 [hingStatusInfoChangedEvent] - ‘bosesoundtouch:30:506583CE0123’ changed from INITIALIZING to ONLINE
2019-01-20 19:16:47.191 [vent.ItemStateChangedEvent] - Stue_Bose_Volume changed from NULL to 24
2019-01-20 19:16:47.476 [vent.ItemStateChangedEvent] - Stue_Bose_Power changed from NULL to OFF
2019-01-20 19:16:49.202 [hingStatusInfoChangedEvent] - ‘knx:ip:bridge’ changed from UNINITIALIZED to INITIALIZING
2019-01-20 19:16:49.399 [hingStatusInfoChangedEvent] - ‘knx:ip:bridge’ changed from INITIALIZING to UNKNOWN
2019-01-20 19:16:50.337 [hingStatusInfoChangedEvent] - ‘knx:device:bridge:generic’ changed from UNINITIALIZED to INITIALIZING
2019-01-20 19:16:50.462 [hingStatusInfoChangedEvent] - ‘knx:device:bridge:generic’ changed from INITIALIZING to OFFLINE (BRIDGE_OFFLINE)
2019-01-20 19:16:50.920 [hingStatusInfoChangedEvent] - ‘samsungtv📺be2f00b0_98d6_4ce1_b9d8_4280a6412249’ changed from UNINITIALIZED to INITIALIZING
2019-01-20 19:16:50.977 [hingStatusInfoChangedEvent] - ‘samsungtv📺be2f00b0_98d6_4ce1_b9d8_4280a6412249’ changed from INITIALIZING to OFFLINE
2019-01-20 19:16:51.079 [vent.ItemStateChangedEvent] - GF_Stue_TV changed from NULL to OFF
2019-01-20 19:16:51.138 [hingStatusInfoChangedEvent] - ‘knx:ip:bridge’ changed from UNKNOWN to ONLINE
2019-01-20 19:16:51.183 [hingStatusInfoChangedEvent] - ‘knx:device:bridge:generic’ changed from OFFLINE (BRIDGE_OFFLINE) to UNKNOWN
2019-01-20 19:16:51.212 [hingStatusInfoChangedEvent] - ‘samsungtv📺be2f00b0_98d6_4ce1_b9d8_4280a6412249’ changed from OFFLINE to ONLINE
2019-01-20 19:16:51.251 [vent.ItemStateChangedEvent] - GF_Stue_TV changed from OFF to ON
2019-01-20 19:16:51.350 [hingStatusInfoChangedEvent] - ‘samsungtv📺19cb6b46_4ad5_fe90_df8c_9b299727521a’ changed from UNINITIALIZED to INITIALIZING
2019-01-20 19:16:51.358 [hingStatusInfoChangedEvent] - ‘samsungtv📺19cb6b46_4ad5_fe90_df8c_9b299727521a’ changed from INITIALIZING to OFFLINE
2019-01-20 19:16:51.456 [vent.ItemStateChangedEvent] - GF_Redskapshus_TV changed from NULL to OFF
2019-01-20 19:16:51.744 [vent.ItemStateChangedEvent] - Volum changed from NULL to 0
2019-01-20 19:16:56.242 [vent.ItemStateChangedEvent] - GF_Redskapshus_Verksted_Temperature changed from NULL to 8.47
2019-01-20 19:16:58.295 [vent.ItemStateChangedEvent] - Varmepumpe_SensorValues_ColdFluidOut changed from NULL to -0.1
2019-01-20 19:16:58.474 [vent.ItemStateChangedEvent] - Varmepumpe_DeviceValues_Fan changed from NULL to OFF
2019-01-20 19:16:58.525 [vent.ItemStateChangedEvent] - GF_Redskapshus_Port4_Lukke changed from NULL to OFF
2019-01-20 19:16:58.580 [vent.ItemStateChangedEvent] - Varmepumpe_SensorValues_AirIntake changed from NULL to -2.8
2019-01-20 19:16:58.644 [vent.ItemStateChangedEvent] - GF_Redskapshus_Light changed from NULL to OFF
2019-01-20 19:16:59.133 [vent.ItemStateChangedEvent] - GF_Redskapshus_Port5_Apne changed from NULL to OFF
2019-01-20 19:16:59.188 [vent.ItemStateChangedEvent] - Varmepumpe_ControlData_CompressorSpeed changed from NULL to 0.1
2019-01-20 19:16:59.238 [vent.ItemStateChangedEvent] - Varmepumpe_DeviceValues_HighPressostat changed from NULL to OFF
2019-01-20 19:16:59.409 [vent.ItemStateChangedEvent] - Varmepumpe_SensorValues_HeatFluidIn changed from NULL to 7.1
2019-01-20 19:16:59.439 [vent.ItemStateChangedEvent] - Varmepumpe_DeviceValues_Compressor changed from NULL to OFF
2019-01-20 19:16:59.486 [vent.ItemStateChangedEvent] - TV changed from NULL to ON
2019-01-20 19:16:59.530 [vent.ItemStateChangedEvent] - Varmepumpe_SensorValues_ColdFluidIn changed from NULL to 8.0
2019-01-20 19:16:59.634 [vent.ItemStateChangedEvent] - GF_Redskapshus_Temperature changed from NULL to -4.9
2019-01-20 19:16:59.721 [vent.ItemStateChangedEvent] - Varmepumpe_SensorValues_Compressor changed from NULL to 2.1
2019-01-20 19:16:59.784 [vent.ItemStateChangedEvent] - Varmepumpe_SensorValues_Indoor changed from NULL to -52.1
2019-01-20 19:16:59.871 [vent.ItemStateChangedEvent] - GF_Verksted_Port_Apne changed from NULL to OFF
2019-01-20 19:17:00.354 [vent.ItemStateChangedEvent] - Home_Hjemme changed from NULL to OFF
2019-01-20 19:17:00.428 [vent.ItemStateChangedEvent] - Varmepumpe_DeviceValues_SwitchValve changed from NULL to ON
2019-01-20 19:17:00.514 [vent.ItemStateChangedEvent] - GF_Redskapshus_Port4_Apne changed from NULL to OFF
2019-01-20 19:17:00.559 [vent.ItemStateChangedEvent] - Varmepumpe_DeviceValues_CollectedPulsesMeter2 changed from NULL to 1.0
2019-01-20 19:17:00.595 [vent.ItemStateChangedEvent] - Varmepumpe_DeviceValues_CollectedPulsesMeter1 changed from NULL to 1.0
2019-01-20 19:17:00.655 [vent.ItemStateChangedEvent] - Varmepumpe_SensorValues_Pool changed from NULL to 0.1
2019-01-20 19:17:00.703 [vent.ItemStateChangedEvent] - GF_Redskapshus_Port2_Lys changed from NULL to OFF
2019-01-20 19:17:00.747 [vent.ItemStateChangedEvent] - GF_Redskapshus_Port2_Apne changed from NULL to OFF
2019-01-20 19:17:01.140 [vent.ItemStateChangedEvent] - GF_Redskapshus_Port2_Lukke changed from NULL to OFF
2019-01-20 19:17:01.181 [vent.ItemStateChangedEvent] - Varmepumpe_DeviceValues_HeatFluidPump changed from NULL to ON
2019-01-20 19:17:01.223 [vent.ItemStateChangedEvent] - Home_Borte changed from NULL to OFF
2019-01-20 19:17:01.262 [vent.ItemStateChangedEvent] - Home_Natt changed from NULL to OFF
2019-01-20 19:17:01.423 [vent.ItemStateChangedEvent] - Varmepumpe_DeviceValues_ColdFluidPump changed from NULL to OFF
2019-01-20 19:17:01.464 [vent.ItemStateChangedEvent] - GF_Redskapshus_Port3_Lys changed from NULL to OFF
2019-01-20 19:17:01.507 [vent.ItemStateChangedEvent] - Varmepumpe_DeviceValues_RadiatorPump changed from NULL to ON
2019-01-20 19:17:01.555 [vent.ItemStateChangedEvent] - GF_Redskapshus_Port5_Lukke changed from NULL to OFF
2019-01-20 19:17:01.609 [vent.ItemStateChangedEvent] - HusdataInterface_SensorValues_RadiatorReturn changed from NULL to 7.5
2019-01-20 19:17:01.659 [vent.ItemStateChangedEvent] - Varmepumpe_DeviceValues_SwitchValve2 changed from NULL to ON
2019-01-20 19:17:01.719 [vent.ItemStateChangedEvent] - GF_Redskapshus_Port4_Lys changed from NULL to OFF
2019-01-20 19:17:01.768 [vent.ItemStateChangedEvent] - GF_Redskapshus_Port3_Apne changed from NULL to OFF
2019-01-20 19:17:02.182 [vent.ItemStateChangedEvent] - Varmepumpe_SensorValues_HeatFluidOut changed from NULL to 8.9
2019-01-20 19:17:02.233 [vent.ItemStateChangedEvent] - TVUE46D8000_Volume changed from NULL to 12.0
2019-01-20 19:17:02.336 [vent.ItemStateChangedEvent] - GF_Verksted_Port_Lukke changed from NULL to OFF
2019-01-20 19:17:02.381 [vent.ItemStateChangedEvent] - GF_Redskapshus_Port3_Lukke changed from NULL to OFF
2019-01-20 19:17:02.419 [vent.ItemStateChangedEvent] - Varmepumpe_SensorValues_Outdoor changed from NULL to -1.7
2019-01-20 19:17:02.464 [vent.ItemStateChangedEvent] - GF_Redskapshus_Port5_Lys changed from NULL to OFF
2019-01-20 19:17:02.584 [vent.ItemStateChangedEvent] - Varmepumpe_SensorValues_HotWater changed from NULL to 30.4
2019-01-20 19:17:04.235 [hingStatusInfoChangedEvent] - ‘knx:device:bridge:generic’ changed from UNKNOWN to OFFLINE
2019-01-20 19:17:10.699 [hingStatusInfoChangedEvent] - ‘bosesoundtouch:30:506583CE0123’ changed from ONLINE to UNINITIALIZED
2019-01-20 19:17:11.837 [hingStatusInfoChangedEvent] - ‘bosesoundtouch:30:506583CE0123’ changed from UNINITIALIZED to OFFLINE (COMMUNICATION_ERROR): Disconnected
2019-01-20 19:17:11.842 [hingStatusInfoChangedEvent] - ‘bosesoundtouch:30:506583CE0123’ changed from OFFLINE (COMMUNICATION_ERROR): Disconnected to UNINITIALIZED (HANDLER_MISSING_ERROR)
2019-01-20 19:17:18.549 [hingStatusInfoChangedEvent] - ‘knx:device:bridge:generic’ changed from OFFLINE to UNINITIALIZED
2019-01-20 19:17:18.566 [hingStatusInfoChangedEvent] - ‘knx:device:bridge:generic’ changed from UNINITIALIZED to UNINITIALIZED (HANDLER_MISSING_ERROR)
2019-01-20 19:17:18.572 [hingStatusInfoChangedEvent] - ‘knx:ip:bridge’ changed from ONLINE to UNINITIALIZED
2019-01-20 19:17:18.627 [hingStatusInfoChangedEvent] - ‘knx:ip:bridge’ changed from UNINITIALIZED to OFFLINE
2019-01-20 19:17:18.647 [hingStatusInfoChangedEvent] - ‘knx:ip:bridge’ changed from OFFLINE to UNINITIALIZED (HANDLER_MISSING_ERROR)
2019-01-20 19:17:18.702 [hingStatusInfoChangedEvent] - ‘samsungtv📺19cb6b46_4ad5_fe90_df8c_9b299727521a’ changed from OFFLINE to UNINITIALIZED
2019-01-20 19:17:18.720 [hingStatusInfoChangedEvent] - ‘samsungtv📺19cb6b46_4ad5_fe90_df8c_9b299727521a’ changed from UNINITIALIZED to UNINITIALIZED (HANDLER_MISSING_ERROR)
2019-01-20 19:17:18.730 [hingStatusInfoChangedEvent] - ‘samsungtv📺be2f00b0_98d6_4ce1_b9d8_4280a6412249’ changed from ONLINE to UNINITIALIZED
2019-01-20 19:17:18.736 [hingStatusInfoChangedEvent] - ‘samsungtv📺be2f00b0_98d6_4ce1_b9d8_4280a6412249’ changed from UNINITIALIZED to UNINITIALIZED (HANDLER_MISSING_ERROR)
2019-01-20 19:17:22.633 [temChannelLinkRemovedEvent] - Link ‘Varmepumpe_SensorValues_HotWater => regoheatpump:serialHusdata:cecec0a8:sensorValues#hotWater’ has been removed.
2019-01-20 19:17:22.637 [temChannelLinkRemovedEvent] - Link ‘HusdataInterface_SensorValues_HeatFluidIn => regoheatpump:serialHusdata:8d9e73fd:sensorValues#heatFluidIn’ has been removed.
2019-01-20 19:17:22.640 [temChannelLinkRemovedEvent] - Link ‘HusdataInterface_SensorValues_RadiatorReturn => regoheatpump:serialHusdata:8f170952:sensorValues#radiatorReturn’ has been removed.
2019-01-20 19:17:22.644 [temChannelLinkRemovedEvent] - Link ‘Varmepumpe_SensorValues_Compressor => regoheatpump:serialHusdata:5a58bd01:sensorValues#compressor’ has been removed.
2019-01-20 19:17:22.648 [temChannelLinkRemovedEvent] - Link ‘TVUE46D8000_Volume => samsungtv📺19cb6b46_4ad5_fe90_df8c_9b299727521a:volume’ has been removed.
2019-01-20 19:17:22.654 [temChannelLinkRemovedEvent] - Link ‘HusdataInterface_SensorValues_Compressor => regoheatpump:serialHusdata:8d9e73fd:sensorValues#compressor’ has been removed.
2019-01-20 19:17:22.657 [temChannelLinkRemovedEvent] - Link ‘HeatFluidPump => regoheatpump:serialHusdata:8d9e73fd:deviceValues#heatFluidPump’ has been removed.
2019-01-20 19:17:22.660 [temChannelLinkRemovedEvent] - Link ‘Varmepumpe_DeviceValues_HighPressostat => regoheatpump:serialHusdata:cecec0a8:deviceValues#highPressostat’ has been removed.
2019-01-20 19:17:22.664 [temChannelLinkRemovedEvent] - Link ‘Alarm => regoheatpump:serialHusdata:8d9e73fd:deviceValues#alarm’ has been removed.
2019-01-20 19:17:22.667 [temChannelLinkRemovedEvent] - Link ‘VPVerksted_SensorValues_RadiatorReturn => regoheatpump:serialHusdata:4f00fe28:sensorValues#radiatorReturn’ has been removed.
2019-01-20 19:17:22.670 [temChannelLinkRemovedEvent] - Link ‘Varmepumpe_Settings_HeatCurveFineTune => regoheatpump:serialHusdata:cecec0a8:settings#heatCurveFineAdj’ has been removed.
2019-01-20 19:17:22.673 [temChannelLinkRemovedEvent] - Link ‘Varmepumpe_DeviceValues_Alarm => regoheatpump:serialHusdata:cecec0a8:deviceValues#alarm’ has been removed.
2019-01-20 19:17:22.676 [temChannelLinkRemovedEvent] - Link ‘Varmepumpe_ControlData_RadiatorForwardTarget => regoheatpump:serialHusdata:5a58bd01:controlData#radiatorForwardTarget’ has been removed.
2019-01-20 19:17:22.678 [temChannelLinkRemovedEvent] - Link ‘Varmepumpe_SensorValues_ExternalHotWater => regoheatpump:serialHusdata:cecec0a8:sensorValues#externalHotWater’ has been removed.
2019-01-20 19:17:22.681 [temChannelLinkRemovedEvent] - Link ‘HusdataInterface_SensorValues_Compressor => regoheatpump:serialHusdata:8f170952:sensorValues#compressor’ has been removed.
2019-01-20 19:17:22.685 [temChannelLinkRemovedEvent] - Link ‘Varmepumpe_DeviceValues_HeatingCable => regoheatpump:serialHusdata:cecec0a8:deviceValues#heatingCable’ has been removed.
2019-01-20 19:17:22.688 [temChannelLinkRemovedEvent] - Link ‘HusdataInterface_SensorValues_Outdoor => regoheatpump:serialHusdata:8d9e73fd:sensorValues#outdoor’ has been removed.
2019-01-20 19:17:22.692 [temChannelLinkRemovedEvent] - Link ‘Stue_Bose_Volume => bosesoundtouch:30:506583CE0123:volume’ has been removed.
2019-01-20 19:17:22.694 [temChannelLinkRemovedEvent] - Link ‘Varmepumpe_ControlData_MaximalHotWater => regoheatpump:serialHusdata:5a58bd01:controlData#hotWaterOff’ has been removed.
2019-01-20 19:17:22.697 [temChannelLinkRemovedEvent] - Link ‘Varmepumpe_DeviceValues_CrankCaseHeater => regoheatpump:serialHusdata:cecec0a8:deviceValues#crankCaseHeater’ has been removed.
2019-01-20 19:17:22.699 [temChannelLinkRemovedEvent] - Link ‘HotWater => regoheatpump:serialHusdata:8d9e73fd:sensorValues#hotWater’ has been removed.
2019-01-20 19:17:22.702 [temChannelLinkRemovedEvent] - Link ‘Varmepumpe_ControlData_HotWaterTarget => regoheatpump:serialHusdata:5a58bd01:controlData#hotWaterTarget’ has been removed.
2019-01-20 19:17:22.705 [temChannelLinkRemovedEvent] - Link ‘GF_Redskapshus_Verksted_Temperature => knx:device:bridge:generic:GF_Redskapshus_Verksted_Temperature’ has been removed.
2019-01-20 19:17:22.707 [temChannelLinkRemovedEvent] - Link ‘Varmepumpe_ControlData_HotWaterTarget => regoheatpump:serialHusdata:cecec0a8:controlData#hotWaterTarget’ has been removed.
2019-01-20 19:17:22.711 [temChannelLinkRemovedEvent] - Link ‘Varmepumpe_ControlData_MinimalHotWater => regoheatpump:serialHusdata:cecec0a8:controlData#hotWaterOn’ has been removed.
2019-01-20 19:17:22.714 [temChannelLinkRemovedEvent] - Link ‘GF_Redskapshus_Light => knx:device:bridge:generic:GF_Redskapshus_Verksted_Light’ has been removed.
2019-01-20 19:17:22.716 [temChannelLinkRemovedEvent] - Link ‘Varmepumpe_SensorValues_ExternalHotWater => regoheatpump:serialHusdata:5a58bd01:sensorValues#externalHotWater’ has been removed.
2019-01-20 19:17:22.719 [temChannelLinkRemovedEvent] - Link ‘Varmepumpe_ControlData_MaximalRadiatorReturn => regoheatpump:serialHusdata:5a58bd01:controlData#radiatorReturnOff’ has been removed.
2019-01-20 19:17:22.722 [temChannelLinkRemovedEvent] - Link ‘Varmepumpe_ControlData_MinimalHotWater => regoheatpump:serialHusdata:5a58bd01:controlData#hotWaterOn’ has been removed.
2019-01-20 19:17:22.725 [temChannelLinkRemovedEvent] - Link ‘Varmepumpe_DeviceValues_Compressor => regoheatpump:serialHusdata:cecec0a8:deviceValues#compressor’ has been removed.
2019-01-20 19:17:22.727 [temChannelLinkRemovedEvent] - Link ‘HusdataInterface_SensorValues_RadiatorReturn => regoheatpump:serialHusdata:5a58bd01:sensorValues#radiatorReturn’ has been removed.
2019-01-20 19:17:22.730 [temChannelLinkRemovedEvent] - Link ‘VPVerksted_SensorValues_Compressor => regoheatpump:serialHusdata:4f00fe28:sensorValues#compressor’ has been removed.
2019-01-20 19:17:22.735 [temChannelLinkRemovedEvent] - Link ‘Varmepumpe_SensorValues_Outdoor => regoheatpump:serialHusdata:cecec0a8:sensorValues#outdoor’ has been removed.
2019-01-20 19:17:22.739 [temChannelLinkRemovedEvent] - Link ‘VPVerksted_SensorValues_HeatFluidIn => regoheatpump:serialHusdata:4f00fe28:sensorValues#heatFluidIn’ has been removed.
2019-01-20 19:17:22.742 [temChannelLinkRemovedEvent] - Link ‘Varmepumpe_DeviceValues_AdditionalHeat6kW => regoheatpump:serialHusdata:cecec0a8:deviceValues#additionalHeat6kW’ has been removed.
2019-01-20 19:17:22.745 [temChannelLinkRemovedEvent] - Link ‘Varmepumpe_SensorValues_HeatFluidOut => regoheatpump:serialHusdata:cecec0a8:sensorValues#heatFluidOut’ has been removed.
2019-01-20 19:17:22.748 [temChannelLinkRemovedEvent] - Link ‘Varmepumpe_SensorValues_ColdFluidIn => regoheatpump:serialHusdata:5a58bd01:sensorValues#coldFluidIn’ has been removed.
2019-01-20 19:17:22.753 [temChannelLinkRemovedEvent] - Link ‘HusdataInterface_SensorValues_RadiatorReturn => regoheatpump:serialHusdata:8d9e73fd:sensorValues#radiatorReturn’ has been removed.
2019-01-20 19:17:22.756 [temChannelLinkRemovedEvent] - Link ‘Compressor => regoheatpump:serialHusdata:8d9e73fd:deviceValues#compressor’ has been removed.
2019-01-20 19:17:22.760 [temChannelLinkRemovedEvent] - Link ‘GF_Redskapshus_Port2_Lys => knx:device:bridge:generic:GF_Redskapshus_Port2_Light’ has been removed.
2019-01-20 19:17:22.763 [temChannelLinkRemovedEvent] - Link ‘VPVerksted_SensorValues_ColdFluidIn => regoheatpump:serialHusdata:4f00fe28:sensorValues#coldFluidIn’ has been removed.
2019-01-20 19:17:22.770 [temChannelLinkRemovedEvent] - Link ‘Varmepumpe_SensorValues_Outdoor => regoheatpump:serialHusdata:5a58bd01:sensorValues#outdoor’ has been removed.
2019-01-20 19:17:22.773 [temChannelLinkRemovedEvent] - Link ‘DeviceValues_Fan => regoheatpump:serialHusdata:8d9e73fd:deviceValues#fan’ has been removed.
2019-01-20 19:17:22.777 [temChannelLinkRemovedEvent] - Link ‘GF_Redskapshus_TV => samsungtv📺19cb6b46_4ad5_fe90_df8c_9b299727521a:power’ has been removed.
2019-01-20 19:17:22.780 [temChannelLinkRemovedEvent] - Link ‘Varmepumpe_SensorValues_Indoor => regoheatpump:serialHusdata:5a58bd01:sensorValues#indoor’ has been removed.
2019-01-20 19:17:22.782 [temChannelLinkRemovedEvent] - Link ‘Varmepumpe_Settings_RoomSensorInfluence => regoheatpump:serialHusdata:cecec0a8:settings#curveInflByInTemp’ has been removed.
2019-01-20 19:17:22.785 [temChannelLinkRemovedEvent] - Link ‘VPVerksted_SensorValues_ColdFluidOut => regoheatpump:serialHusdata:4f00fe28:sensorValues#coldFluidOut’ has been removed.
2019-01-20 19:17:22.789 [temChannelLinkRemovedEvent] - Link ‘HusdataInterface_SensorValues_ColdFluidOut => regoheatpump:serialHusdata:8d9e73fd:sensorValues#coldFluidOut’ has been removed.
2019-01-20 19:17:22.792 [temChannelLinkRemovedEvent] - Link ‘Varmepumpe_DeviceValues_Fan => regoheatpump:serialHusdata:cecec0a8:deviceValues#fan’ has been removed.
2019-01-20 19:17:22.796 [temChannelLinkRemovedEvent] - Link ‘Varmepumpe_ControlData_RadiatorReturnTarget => regoheatpump:serialHusdata:cecec0a8:controlData#radiatorReturnTarget’ has been removed.
2019-01-20 19:17:22.799 [temChannelLinkRemovedEvent] - Link ‘RadiatorForward => regoheatpump:serialHusdata:8d9e73fd:sensorValues#radiatorForward’ has been removed.
2019-01-20 19:17:22.802 [temChannelLinkRemovedEvent] - Link ‘Varmepumpe_DeviceValues_AdditionalHeat3kW => regoheatpump:serialHusdata:cecec0a8:deviceValues#additionalHeat3kW’ has been removed.
2019-01-20 19:17:22.805 [temChannelLinkRemovedEvent] - Link ‘RadiatorPump => regoheatpump:serialHusdata:8d9e73fd:deviceValues#radiatorPump’ has been removed.
2019-01-20 19:17:22.808 [temChannelLinkRemovedEvent] - Link ‘Varmepumpe_SensorValues_HeatFluidIn => regoheatpump:serialHusdata:cecec0a8:sensorValues#heatFluidIn’ has been removed.
2019-01-20 19:17:22.811 [temChannelLinkRemovedEvent] - Link ‘Varmepumpe_SensorValues_Pool => regoheatpump:serialHusdata:5a58bd01:sensorValues#pool’ has been removed.
2019-01-20 19:17:22.815 [temChannelLinkRemovedEvent] - Link ‘Varmepumpe_SensorValues_Indoor => regoheatpump:serialHusdata:cecec0a8:sensorValues#indoor’ has been removed.
2019-01-20 19:17:22.817 [temChannelLinkRemovedEvent] - Link ‘Varmepumpe_SensorValues_RadiatorForward => regoheatpump:serialHusdata:5a58bd01:sensorValues#radiatorForward’ has been removed.
2019-01-20 19:17:22.820 [temChannelLinkRemovedEvent] - Link ‘AirIntake => regoheatpump:serialHusdata:8d9e73fd:sensorValues#airIntake’ has been removed.
2019-01-20 19:17:22.823 [temChannelLinkRemovedEvent] - Link ‘Varmepumpe_ControlData_AdditionalHeatPower => regoheatpump:serialHusdata:cecec0a8:controlData#addHeatPowerEnergy’ has been removed.
2019-01-20 19:17:22.826 [temChannelLinkRemovedEvent] - Link ‘Varmepumpe_ControlData_MinimalRadiatorReturn => regoheatpump:serialHusdata:cecec0a8:controlData#radiatorReturnOn’ has been removed.
2019-01-20 19:17:22.829 [temChannelLinkRemovedEvent] - Link ‘VPVerksted_SensorValues_HeatFluidOut => regoheatpump:serialHusdata:4f00fe28:sensorValues#heatFluidOut’ has been removed.
2019-01-20 19:17:22.832 [temChannelLinkRemovedEvent] - Link ‘HusdataInterface_Settings_HeatCurve2 => regoheatpump:serialHusdata:5a58bd01:settings#heatCurve2’ has been removed.
2019-01-20 19:17:22.835 [temChannelLinkRemovedEvent] - Link ‘HusdataInterface_SensorValues_HeatFluidOut => regoheatpump:serialHusdata:8d9e73fd:sensorValues#heatFluidOut’ has been removed.
2019-01-20 19:17:22.838 [temChannelLinkRemovedEvent] - Link ‘Varmepumpe_DeviceValues_CollectedPulsesMeter2 => regoheatpump:serialHusdata:cecec0a8:deviceValues#elMeter2’ has been removed.
2019-01-20 19:17:22.840 [temChannelLinkRemovedEvent] - Link ‘HusdataInterface_SensorValues_HeatFluidIn => regoheatpump:serialHusdata:8f170952:sensorValues#heatFluidIn’ has been removed.
2019-01-20 19:17:22.843 [temChannelLinkRemovedEvent] - Link ‘HusdataInterface_SensorValues_HeatFluidOut => regoheatpump:serialHusdata:8f170952:sensorValues#heatFluidOut’ has been removed.
2019-01-20 19:17:22.846 [temChannelLinkRemovedEvent] - Link ‘Varmepumpe_DeviceValues_CollectedPulsesMeter1 => regoheatpump:serialHusdata:cecec0a8:deviceValues#elMeter1’ has been removed.
2019-01-20 19:17:22.849 [temChannelLinkRemovedEvent] - Link ‘Varmepumpe_DeviceValues_ColdFluidPump => regoheatpump:serialHusdata:cecec0a8:deviceValues#coldFluidPump’ has been removed.
2019-01-20 19:17:22.852 [temChannelLinkRemovedEvent] - Link ‘SwitchValve => regoheatpump:serialHusdata:8d9e73fd:deviceValues#switchValve’ has been removed.
2019-01-20 19:17:22.855 [temChannelLinkRemovedEvent] - Link ‘Varmepumpe_DeviceValues_RadiatorPump => regoheatpump:serialHusdata:cecec0a8:deviceValues#radiatorPump’ has been removed.
2019-01-20 19:17:22.858 [temChannelLinkRemovedEvent] - Link ‘Varmepumpe_ControlData_MinimalRadiatorReturn => regoheatpump:serialHusdata:5a58bd01:controlData#radiatorReturnOn’ has been removed.
2019-01-20 19:17:22.861 [temChannelLinkRemovedEvent] - Link ‘HusdataInterface_SensorValues_ColdFluidIn => regoheatpump:serialHusdata:8f170952:sensorValues#coldFluidIn’ has been removed.
2019-01-20 19:17:22.863 [temChannelLinkRemovedEvent] - Link ‘HusdataInterface_SensorValues_Outdoor => regoheatpump:serialHusdata:8f170952:sensorValues#outdoor’ has been removed.
2019-01-20 19:17:22.867 [temChannelLinkRemovedEvent] - Link ‘Volum => samsungtv📺be2f00b0_98d6_4ce1_b9d8_4280a6412249:volume’ has been removed.
2019-01-20 19:17:22.869 [temChannelLinkRemovedEvent] - Link ‘GF_Redskapshus_Port4_Lys => knx:device:bridge:generic:GF_Redskapshus_Port4_Light’ has been removed.
2019-01-20 19:17:22.872 [temChannelLinkRemovedEvent] - Link ‘Varmepumpe_ControlData_MaximalRadiatorReturn => regoheatpump:serialHusdata:cecec0a8:controlData#radiatorReturnOff’ has been removed.
2019-01-20 19:17:22.876 [temChannelLinkRemovedEvent] - Link ‘Varmepumpe_ControlData_AdditionalHeatPower => regoheatpump:serialHusdata:cecec0a8:controlData#addHeatPowerPercent’ has been removed.
2019-01-20 19:17:22.879 [temChannelLinkRemovedEvent] - Link ‘GF_Stue_TV => samsungtv📺be2f00b0_98d6_4ce1_b9d8_4280a6412249:power’ has been removed.
2019-01-20 19:17:22.882 [temChannelLinkRemovedEvent] - Link ‘Varmepumpe_DeviceValues_LowPressostat => regoheatpump:serialHusdata:cecec0a8:deviceValues#lowPressostat’ has been removed.
2019-01-20 19:17:22.885 [temChannelLinkRemovedEvent] - Link ‘Varmepumpe_ControlData_MaximalHotWater => regoheatpump:serialHusdata:cecec0a8:controlData#hotWaterOff’ has been removed.
2019-01-20 19:17:22.888 [temChannelLinkRemovedEvent] - Link ‘GF_Redskapshus_Temperature => knx:device:bridge:generic:GF_Redskapshus_Temperature’ has been removed.
2019-01-20 19:17:22.891 [temChannelLinkRemovedEvent] - Link ‘ColdFluidPump => regoheatpump:serialHusdata:8d9e73fd:deviceValues#coldFluidPump’ has been removed.
2019-01-20 19:17:22.894 [temChannelLinkRemovedEvent] - Link ‘Stue_Bose_Power => bosesoundtouch:30:506583CE0123:power’ has been removed.
2019-01-20 19:17:22.897 [temChannelLinkRemovedEvent] - Link ‘Varmepumpe_DeviceValues_HeatFluidPump => regoheatpump:serialHusdata:cecec0a8:deviceValues#heatFluidPump’ has been removed.
2019-01-20 19:17:22.900 [temChannelLinkRemovedEvent] - Link ‘Varmepumpe_SensorValues_AirIntake => regoheatpump:serialHusdata:5a58bd01:sensorValues#airIntake’ has been removed.
2019-01-20 19:17:22.903 [temChannelLinkRemovedEvent] - Link ‘Varmepumpe_SensorValues_RadiatorForward => regoheatpump:serialHusdata:cecec0a8:sensorValues#radiatorForward’ has been removed.
2019-01-20 19:17:22.909 [temChannelLinkRemovedEvent] - Link ‘Varmepumpe_DeviceValues_SwitchValve => regoheatpump:serialHusdata:cecec0a8:deviceValues#switchValve’ has been removed.
2019-01-20 19:17:22.912 [temChannelLinkRemovedEvent] - Link ‘Varmepumpe_SensorValues_HeatFluidIn => regoheatpump:serialHusdata:5a58bd01:sensorValues#heatFluidIn’ has been removed.
2019-01-20 19:17:22.915 [temChannelLinkRemovedEvent] - Link ‘Varmepumpe_SensorValues_Compressor => regoheatpump:serialHusdata:cecec0a8:sensorValues#compressor’ has been removed.
2019-01-20 19:17:22.918 [temChannelLinkRemovedEvent] - Link ‘Varmepumpe_SensorValues_RadiatorReturn => regoheatpump:serialHusdata:cecec0a8:sensorValues#radiatorReturn’ has been removed.
2019-01-20 19:17:22.921 [temChannelLinkRemovedEvent] - Link ‘HusdataInterface_SensorValues_ColdFluidIn => regoheatpump:serialHusdata:8d9e73fd:sensorValues#coldFluidIn’ has been removed.
2019-01-20 19:17:22.924 [temChannelLinkRemovedEvent] - Link ‘Varmepumpe_SensorValues_ColdFluidOut => regoheatpump:serialHusdata:cecec0a8:sensorValues#coldFluidOut’ has been removed.
2019-01-20 19:17:22.927 [temChannelLinkRemovedEvent] - Link ‘Varmepumpe_SensorValues_Pool => regoheatpump:serialHusdata:cecec0a8:sensorValues#pool’ has been removed.
2019-01-20 19:17:22.930 [temChannelLinkRemovedEvent] - Link ‘Varmepumpe_SensorValues_Outdoor => regoheatpump:serialHusdata:12eb66d3:sensorValues#outdoor’ has been removed.
2019-01-20 19:17:22.933 [temChannelLinkRemovedEvent] - Link ‘Varmepumpe_ControlData_RadiatorForwardTarget => regoheatpump:serialHusdata:cecec0a8:controlData#radiatorForwardTarget’ has been removed.
2019-01-20 19:17:22.936 [temChannelLinkRemovedEvent] - Link ‘ExternalHotWater => regoheatpump:serialHusdata:8d9e73fd:sensorValues#externalHotWater’ has been removed.
2019-01-20 19:17:22.939 [temChannelLinkRemovedEvent] - Link ‘GF_Redskapshus_Port5_Lys => knx:device:bridge:generic:GF_Redskapshus_Port5_Light’ has been removed.
2019-01-20 19:17:22.942 [temChannelLinkRemovedEvent] - Link ‘Varmepumpe_SensorValues_ColdFluidOut => regoheatpump:serialHusdata:5a58bd01:sensorValues#coldFluidOut’ has been removed.
2019-01-20 19:17:22.945 [temChannelLinkRemovedEvent] - Link ‘Varmepumpe_DeviceValues_SwitchValve2 => regoheatpump:serialHusdata:cecec0a8:deviceValues#switchValve2’ has been removed.
2019-01-20 19:17:22.953 [temChannelLinkRemovedEvent] - Link ‘GF_Redskapshus_Port3_Lys => knx:device:bridge:generic:GF_Redskapshus_Port3_Light’ has been removed.
2019-01-20 19:17:22.957 [temChannelLinkRemovedEvent] - Link ‘Varmepumpe_SensorValues_ColdFluidIn => regoheatpump:serialHusdata:cecec0a8:sensorValues#coldFluidIn’ has been removed.
2019-01-20 19:17:22.960 [temChannelLinkRemovedEvent] - Link ‘Varmepumpe_SensorValues_AirIntake => regoheatpump:serialHusdata:cecec0a8:sensorValues#airIntake’ has been removed.
2019-01-20 19:17:22.964 [temChannelLinkRemovedEvent] - Link ‘Varmepumpe_SensorValues_Compressor => regoheatpump:serialHusdata:12eb66d3:sensorValues#compressor’ has been removed.
2019-01-20 19:17:22.968 [temChannelLinkRemovedEvent] - Link ‘Varmepumpe_ControlData_RadiatorReturnTarget => regoheatpump:serialHusdata:5a58bd01:controlData#radiatorReturnTarget’ has been removed.
2019-01-20 19:17:22.971 [temChannelLinkRemovedEvent] - Link ‘Varmepumpe_SensorValues_HotWater => regoheatpump:serialHusdata:5a58bd01:sensorValues#hotWater’ has been removed.
2019-01-20 19:17:22.974 [temChannelLinkRemovedEvent] - Link ‘Varmepumpe_ControlData_AdditionalHeatPower => regoheatpump:serialHusdata:5a58bd01:controlData#addHeatPowerPercent’ has been removed.
2019-01-20 19:17:22.977 [temChannelLinkRemovedEvent] - Link ‘Varmepumpe_Settings_HeatCurve => regoheatpump:serialHusdata:cecec0a8:settings#heatCurve’ has been removed.
2019-01-20 19:17:22.980 [temChannelLinkRemovedEvent] - Link ‘Varmepumpe_SensorValues_HeatFluidOut => regoheatpump:serialHusdata:5a58bd01:sensorValues#heatFluidOut’ has been removed.
2019-01-20 19:17:22.983 [temChannelLinkRemovedEvent] - Link ‘AdditionalHeat3kW => regoheatpump:serialHusdata:8d9e73fd:deviceValues#additionalHeat3kW’ has been removed.
2019-01-20 19:17:22.985 [temChannelLinkRemovedEvent] - Link ‘HusdataInterface_SensorValues_ColdFluidOut => regoheatpump:serialHusdata:8f170952:sensorValues#coldFluidOut’ has been removed.
2019-01-20 19:17:22.989 [temChannelLinkRemovedEvent] - Link ‘Varmepumpe_ControlData_CompressorSpeed => regoheatpump:serialHusdata:cecec0a8:controlData#compressorSpeed’ has been removed.
2019-01-20 19:17:22.991 [temChannelLinkRemovedEvent] - Link ‘Varmepumpe_Settings_IndoorTarget => regoheatpump:serialHusdata:cecec0a8:settings#indoorTempSetting’ has been removed.
2019-01-20 19:17:22.994 [temChannelLinkRemovedEvent] - Link ‘VPVerksted_SensorValues_Outdoor => regoheatpump:serialHusdata:4f00fe28:sensorValues#outdoor’ has been removed.
==> /var/log/openhab2/openhab.log <==
2019-01-20 19:18:36.576 [ERROR] [org.openhab.binding.regoheatpump ] - FrameworkEvent ERROR - org.openhab.binding.regoheatpump
org.osgi.framework.BundleException: Could not resolve module: org.openhab.binding.regoheatpump [236]
Another singleton bundle selected: osgi.identity; type=“osgi.bundle”; version:Version=“2.5.0.201901142229”; osgi.identity=“org.openhab.binding.regoheatpump”; singleton:=“true”
2019-01-20 19:18:39.520 [INFO ] [.core.internal.i18n.I18nProviderImpl] - Time zone set to ‘Europe/Oslo’.
2019-01-20 19:18:39.541 [INFO ] [.core.internal.i18n.I18nProviderImpl] - Location set to ‘62.751528400000005,7.249154’.
2019-01-20 19:18:57.631 [INFO ] [el.core.internal.ModelRepositoryImpl] - Loading model ‘lunheim.items’
2019-01-20 19:18:59.265 [WARN ] [el.core.internal.ModelRepositoryImpl] - Configuration model ‘mapdb.persist’ has errors, therefore ignoring it: [10,1]: missing EOF at ‘default’
2019-01-20 19:18:59.397 [INFO ] [el.core.internal.ModelRepositoryImpl] - Loading model ‘influxdb.persist’
2019-01-20 19:19:05.401 [INFO ] [thome.model.lsp.internal.ModelServer] - Started Language Server Protocol (LSP) service on port 5007
2019-01-20 19:19:07.544 [INFO ] [el.core.internal.ModelRepositoryImpl] - Loading model ‘lunheim.sitemap’
2019-01-20 19:19:08.318 [INFO ] [el.core.internal.ModelRepositoryImpl] - Loading model ‘knx.things’
==> /var/log/openhab2/events.log <==
2019-01-20 19:19:08.957 [.ItemChannelLinkAddedEvent] - Link ‘Varmepumpe_SensorValues_HotWater-regoheatpump:serialHusdata:cecec0a8:sensorValues#hotWater’ has been added.
2019-01-20 19:19:08.972 [.ItemChannelLinkAddedEvent] - Link ‘HusdataInterface_SensorValues_HeatFluidIn-regoheatpump:serialHusdata:8d9e73fd:sensorValues#heatFluidIn’ has been added.
2019-01-20 19:19:08.983 [.ItemChannelLinkAddedEvent] - Link ‘HusdataInterface_SensorValues_RadiatorReturn-regoheatpump:serialHusdata:8f170952:sensorValues#radiatorReturn’ has been added.
2019-01-20 19:19:08.989 [.ItemChannelLinkAddedEvent] - Link ‘Varmepumpe_SensorValues_Compressor-regoheatpump:serialHusdata:5a58bd01:sensorValues#compressor’ has been added.
2019-01-20 19:19:08.994 [.ItemChannelLinkAddedEvent] - Link ‘TVUE46D8000_Volume-samsungtv📺19cb6b46_4ad5_fe90_df8c_9b299727521a:volume’ has been added.
2019-01-20 19:19:08.998 [.ItemChannelLinkAddedEvent] - Link ‘HusdataInterface_SensorValues_Compressor-regoheatpump:serialHusdata:8d9e73fd:sensorValues#compressor’ has been added.
2019-01-20 19:19:09.007 [.ItemChannelLinkAddedEvent] - Link ‘HeatFluidPump-regoheatpump:serialHusdata:8d9e73fd:deviceValues#heatFluidPump’ has been added.
2019-01-20 19:19:09.014 [.ItemChannelLinkAddedEvent] - Link ‘Varmepumpe_DeviceValues_HighPressostat-regoheatpump:serialHusdata:cecec0a8:deviceValues#highPressostat’ has been added.
2019-01-20 19:19:09.021 [.ItemChannelLinkAddedEvent] - Link ‘Alarm-regoheatpump:serialHusdata:8d9e73fd:deviceValues#alarm’ has been added.
2019-01-20 19:19:09.026 [.ItemChannelLinkAddedEvent] - Link ‘VPVerksted_SensorValues_RadiatorReturn-regoheatpump:serialHusdata:4f00fe28:sensorValues#radiatorReturn’ has been added.
2019-01-20 19:19:09.032 [.ItemChannelLinkAddedEvent] - Link ‘Varmepumpe_Settings_HeatCurveFineTune-regoheatpump:serialHusdata:cecec0a8:settings#heatCurveFineAdj’ has been added.
2019-01-20 19:19:09.035 [.ItemChannelLinkAddedEvent] - Link ‘Varmepumpe_DeviceValues_Alarm-regoheatpump:serialHusdata:cecec0a8:deviceValues#alarm’ has been added.
2019-01-20 19:19:09.039 [.ItemChannelLinkAddedEvent] - Link ‘Varmepumpe_ControlData_RadiatorForwardTarget-regoheatpump:serialHusdata:5a58bd01:controlData#radiatorForwardTarget’ has been added.
2019-01-20 19:19:09.042 [.ItemChannelLinkAddedEvent] - Link ‘Varmepumpe_SensorValues_ExternalHotWater-regoheatpump:serialHusdata:cecec0a8:sensorValues#externalHotWater’ has been added.
2019-01-20 19:19:09.048 [.ItemChannelLinkAddedEvent] - Link ‘HusdataInterface_SensorValues_Compressor-regoheatpump:serialHusdata:8f170952:sensorValues#compressor’ has been added.
2019-01-20 19:19:09.053 [.ItemChannelLinkAddedEvent] - Link ‘Varmepumpe_DeviceValues_HeatingCable-regoheatpump:serialHusdata:cecec0a8:deviceValues#heatingCable’ has been added.
2019-01-20 19:19:09.064 [.ItemChannelLinkAddedEvent] - Link ‘HusdataInterface_SensorValues_Outdoor-regoheatpump:serialHusdata:8d9e73fd:sensorValues#outdoor’ has been added.
2019-01-20 19:19:09.070 [.ItemChannelLinkAddedEvent] - Link ‘Stue_Bose_Volume-bosesoundtouch:30:506583CE0123:volume’ has been added.
2019-01-20 19:19:09.079 [.ItemChannelLinkAddedEvent] - Link ‘Varmepumpe_ControlData_MaximalHotWater-regoheatpump:serialHusdata:5a58bd01:controlData#hotWaterOff’ has been added.
2019-01-20 19:19:09.087 [.ItemChannelLinkAddedEvent] - Link ‘Varmepumpe_DeviceValues_CrankCaseHeater-regoheatpump:serialHusdata:cecec0a8:deviceValues#crankCaseHeater’ has been added.
2019-01-20 19:19:09.095 [.ItemChannelLinkAddedEvent] - Link ‘HotWater-regoheatpump:serialHusdata:8d9e73fd:sensorValues#hotWater’ has been added.
2019-01-20 19:19:09.103 [.ItemChannelLinkAddedEvent] - Link ‘Varmepumpe_ControlData_HotWaterTarget-regoheatpump:serialHusdata:5a58bd01:controlData#hotWaterTarget’ has been added.
2019-01-20 19:19:09.109 [.ItemChannelLinkAddedEvent] - Link ‘GF_Redskapshus_Verksted_Temperature-knx:device:bridge:generic:GF_Redskapshus_Verksted_Temperature’ has been added.
2019-01-20 19:19:09.112 [.ItemChannelLinkAddedEvent] - Link ‘Varmepumpe_ControlData_HotWaterTarget-regoheatpump:serialHusdata:cecec0a8:controlData#hotWaterTarget’ has been added.
2019-01-20 19:19:09.116 [.ItemChannelLinkAddedEvent] - Link ‘Varmepumpe_ControlData_MinimalHotWater-regoheatpump:serialHusdata:cecec0a8:controlData#hotWaterOn’ has been added.
2019-01-20 19:19:09.124 [.ItemChannelLinkAddedEvent] - Link ‘GF_Redskapshus_Light-knx:device:bridge:generic:GF_Redskapshus_Verksted_Light’ has been added.
2019-01-20 19:19:09.127 [.ItemChannelLinkAddedEvent] - Link ‘Varmepumpe_SensorValues_ExternalHotWater-regoheatpump:serialHusdata:5a58bd01:sensorValues#externalHotWater’ has been added.
2019-01-20 19:19:09.137 [.ItemChannelLinkAddedEvent] - Link ‘Varmepumpe_ControlData_MaximalRadiatorReturn-regoheatpump:serialHusdata:5a58bd01:controlData#radiatorReturnOff’ has been added.
2019-01-20 19:19:09.140 [.ItemChannelLinkAddedEvent] - Link ‘Varmepumpe_ControlData_MinimalHotWater-regoheatpump:serialHusdata:5a58bd01:controlData#hotWaterOn’ has been added.
2019-01-20 19:19:09.148 [.ItemChannelLinkAddedEvent] - Link ‘Varmepumpe_DeviceValues_Compressor-regoheatpump:serialHusdata:cecec0a8:deviceValues#compressor’ has been added.
2019-01-20 19:19:09.155 [.ItemChannelLinkAddedEvent] - Link ‘HusdataInterface_SensorValues_RadiatorReturn-regoheatpump:serialHusdata:5a58bd01:sensorValues#radiatorReturn’ has been added.
2019-01-20 19:19:09.160 [.ItemChannelLinkAddedEvent] - Link ‘VPVerksted_SensorValues_Compressor-regoheatpump:serialHusdata:4f00fe28:sensorValues#compressor’ has been added.
2019-01-20 19:19:09.164 [.ItemChannelLinkAddedEvent] - Link ‘Varmepumpe_SensorValues_Outdoor-regoheatpump:serialHusdata:cecec0a8:sensorValues#outdoor’ has been added.
2019-01-20 19:19:09.171 [.ItemChannelLinkAddedEvent] - Link ‘VPVerksted_SensorValues_HeatFluidIn-regoheatpump:serialHusdata:4f00fe28:sensorValues#heatFluidIn’ has been added.
2019-01-20 19:19:09.177 [.ItemChannelLinkAddedEvent] - Link ‘Varmepumpe_DeviceValues_AdditionalHeat6kW-regoheatpump:serialHusdata:cecec0a8:deviceValues#additionalHeat6kW’ has been added.
2019-01-20 19:19:09.185 [.ItemChannelLinkAddedEvent] - Link ‘Varmepumpe_SensorValues_HeatFluidOut-regoheatpump:serialHusdata:cecec0a8:sensorValues#heatFluidOut’ has been added.
2019-01-20 19:19:09.192 [.ItemChannelLinkAddedEvent] - Link ‘Varmepumpe_SensorValues_ColdFluidIn-regoheatpump:serialHusdata:5a58bd01:sensorValues#coldFluidIn’ has been added.
2019-01-20 19:19:09.199 [.ItemChannelLinkAddedEvent] - Link ‘HusdataInterface_SensorValues_RadiatorReturn-regoheatpump:serialHusdata:8d9e73fd:sensorValues#radiatorReturn’ has been added.
2019-01-20 19:19:09.206 [.ItemChannelLinkAddedEvent] - Link ‘Compressor-regoheatpump:serialHusdata:8d9e73fd:deviceValues#compressor’ has been added.
2019-01-20 19:19:09.213 [.ItemChannelLinkAddedEvent] - Link ‘GF_Redskapshus_Port2_Lys-knx:device:bridge:generic:GF_Redskapshus_Port2_Light’ has been added.
2019-01-20 19:19:09.221 [.ItemChannelLinkAddedEvent] - Link ‘VPVerksted_SensorValues_ColdFluidIn-regoheatpump:serialHusdata:4f00fe28:sensorValues#coldFluidIn’ has been added.
2019-01-20 19:19:09.227 [.ItemChannelLinkAddedEvent] - Link ‘Varmepumpe_SensorValues_Outdoor-regoheatpump:serialHusdata:5a58bd01:sensorValues#outdoor’ has been added.
2019-01-20 19:19:09.243 [.ItemChannelLinkAddedEvent] - Link ‘DeviceValues_Fan-regoheatpump:serialHusdata:8d9e73fd:deviceValues#fan’ has been added.
2019-01-20 19:19:09.251 [.ItemChannelLinkAddedEvent] - Link ‘GF_Redskapshus_TV-samsungtv📺19cb6b46_4ad5_fe90_df8c_9b299727521a:power’ has been added.
2019-01-20 19:19:09.257 [.ItemChannelLinkAddedEvent] - Link ‘Varmepumpe_SensorValues_Indoor-regoheatpump:serialHusdata:5a58bd01:sensorValues#indoor’ has been added.
2019-01-20 19:19:09.264 [.ItemChannelLinkAddedEvent] - Link ‘Varmepumpe_Settings_RoomSensorInfluence-regoheatpump:serialHusdata:cecec0a8:settings#curveInflByInTemp’ has been added.
2019-01-20 19:19:09.267 [.ItemChannelLinkAddedEvent] - Link ‘VPVerksted_SensorValues_ColdFluidOut-regoheatpump:serialHusdata:4f00fe28:sensorValues#coldFluidOut’ has been added.
2019-01-20 19:19:09.272 [.ItemChannelLinkAddedEvent] - Link ‘HusdataInterface_SensorValues_ColdFluidOut-regoheatpump:serialHusdata:8d9e73fd:sensorValues#coldFluidOut’ has been added.
2019-01-20 19:19:09.281 [.ItemChannelLinkAddedEvent] - Link ‘Varmepumpe_DeviceValues_Fan-regoheatpump:serialHusdata:cecec0a8:deviceValues#fan’ has been added.
2019-01-20 19:19:09.284 [.ItemChannelLinkAddedEvent] - Link ‘Varmepumpe_ControlData_RadiatorReturnTarget-regoheatpump:serialHusdata:cecec0a8:controlData#radiatorReturnTarget’ has been added.
2019-01-20 19:19:09.291 [.ItemChannelLinkAddedEvent] - Link ‘RadiatorForward-regoheatpump:serialHusdata:8d9e73fd:sensorValues#radiatorForward’ has been added.
2019-01-20 19:19:09.295 [.ItemChannelLinkAddedEvent] - Link ‘Varmepumpe_DeviceValues_AdditionalHeat3kW-regoheatpump:serialHusdata:cecec0a8:deviceValues#additionalHeat3kW’ has been added.
2019-01-20 19:19:09.298 [.ItemChannelLinkAddedEvent] - Link ‘RadiatorPump-regoheatpump:serialHusdata:8d9e73fd:deviceValues#radiatorPump’ has been added.
2019-01-20 19:19:09.301 [.ItemChannelLinkAddedEvent] - Link ‘Varmepumpe_SensorValues_HeatFluidIn-regoheatpump:serialHusdata:cecec0a8:sensorValues#heatFluidIn’ has been added.
2019-01-20 19:19:09.304 [.ItemChannelLinkAddedEvent] - Link ‘Varmepumpe_SensorValues_Pool-regoheatpump:serialHusdata:5a58bd01:sensorValues#pool’ has been added.
2019-01-20 19:19:09.307 [.ItemChannelLinkAddedEvent] - Link ‘Varmepumpe_SensorValues_Indoor-regoheatpump:serialHusdata:cecec0a8:sensorValues#indoor’ has been added.
2019-01-20 19:19:09.310 [.ItemChannelLinkAddedEvent] - Link ‘Varmepumpe_SensorValues_RadiatorForward-regoheatpump:serialHusdata:5a58bd01:sensorValues#radiatorForward’ has been added.
2019-01-20 19:19:09.313 [.ItemChannelLinkAddedEvent] - Link ‘AirIntake-regoheatpump:serialHusdata:8d9e73fd:sensorValues#airIntake’ has been added.
2019-01-20 19:19:09.316 [.ItemChannelLinkAddedEvent] - Link ‘Varmepumpe_ControlData_AdditionalHeatPower-regoheatpump:serialHusdata:cecec0a8:controlData#addHeatPowerEnergy’ has been added.
2019-01-20 19:19:09.319 [.ItemChannelLinkAddedEvent] - Link ‘Varmepumpe_ControlData_MinimalRadiatorReturn-regoheatpump:serialHusdata:cecec0a8:controlData#radiatorReturnOn’ has been added.
2019-01-20 19:19:09.324 [.ItemChannelLinkAddedEvent] - Link ‘VPVerksted_SensorValues_HeatFluidOut-regoheatpump:serialHusdata:4f00fe28:sensorValues#heatFluidOut’ has been added.
2019-01-20 19:19:09.329 [.ItemChannelLinkAddedEvent] - Link ‘HusdataInterface_Settings_HeatCurve2-regoheatpump:serialHusdata:5a58bd01:settings#heatCurve2’ has been added.
2019-01-20 19:19:09.332 [.ItemChannelLinkAddedEvent] - Link ‘HusdataInterface_SensorValues_HeatFluidOut-regoheatpump:serialHusdata:8d9e73fd:sensorValues#heatFluidOut’ has been added.
2019-01-20 19:19:09.334 [.ItemChannelLinkAddedEvent] - Link ‘Varmepumpe_DeviceValues_CollectedPulsesMeter2-regoheatpump:serialHusdata:cecec0a8:deviceValues#elMeter2’ has been added.
2019-01-20 19:19:09.337 [.ItemChannelLinkAddedEvent] - Link ‘HusdataInterface_SensorValues_HeatFluidIn-regoheatpump:serialHusdata:8f170952:sensorValues#heatFluidIn’ has been added.
2019-01-20 19:19:09.342 [.ItemChannelLinkAddedEvent] - Link ‘HusdataInterface_SensorValues_HeatFluidOut-regoheatpump:serialHusdata:8f170952:sensorValues#heatFluidOut’ has been added.
2019-01-20 19:19:09.345 [.ItemChannelLinkAddedEvent] - Link ‘Varmepumpe_DeviceValues_CollectedPulsesMeter1-regoheatpump:serialHusdata:cecec0a8:deviceValues#elMeter1’ has been added.
2019-01-20 19:19:09.347 [.ItemChannelLinkAddedEvent] - Link ‘Varmepumpe_DeviceValues_ColdFluidPump-regoheatpump:serialHusdata:cecec0a8:deviceValues#coldFluidPump’ has been added.
2019-01-20 19:19:09.357 [.ItemChannelLinkAddedEvent] - Link ‘SwitchValve-regoheatpump:serialHusdata:8d9e73fd:deviceValues#switchValve’ has been added.
2019-01-20 19:19:09.360 [.ItemChannelLinkAddedEvent] - Link ‘Varmepumpe_DeviceValues_RadiatorPump-regoheatpump:serialHusdata:cecec0a8:deviceValues#radiatorPump’ has been added.
2019-01-20 19:19:09.365 [.ItemChannelLinkAddedEvent] - Link ‘Varmepumpe_ControlData_MinimalRadiatorReturn-regoheatpump:serialHusdata:5a58bd01:controlData#radiatorReturnOn’ has been added.
2019-01-20 19:19:09.368 [.ItemChannelLinkAddedEvent] - Link ‘HusdataInterface_SensorValues_ColdFluidIn-regoheatpump:serialHusdata:8f170952:sensorValues#coldFluidIn’ has been added.
2019-01-20 19:19:09.371 [.ItemChannelLinkAddedEvent] - Link ‘HusdataInterface_SensorValues_Outdoor-regoheatpump:serialHusdata:8f170952:sensorValues#outdoor’ has been added.
2019-01-20 19:19:09.374 [.ItemChannelLinkAddedEvent] - Link ‘Volum-samsungtv📺be2f00b0_98d6_4ce1_b9d8_4280a6412249:volume’ has been added.
2019-01-20 19:19:09.378 [.ItemChannelLinkAddedEvent] - Link ‘GF_Redskapshus_Port4_Lys-knx:device:bridge:generic:GF_Redskapshus_Port4_Light’ has been added.
2019-01-20 19:19:09.381 [.ItemChannelLinkAddedEvent] - Link ‘Varmepumpe_ControlData_MaximalRadiatorReturn-regoheatpump:serialHusdata:cecec0a8:controlData#radiatorReturnOff’ has been added.
2019-01-20 19:19:09.384 [.ItemChannelLinkAddedEvent] - Link ‘Varmepumpe_ControlData_AdditionalHeatPower-regoheatpump:serialHusdata:cecec0a8:controlData#addHeatPowerPercent’ has been added.
2019-01-20 19:19:09.387 [.ItemChannelLinkAddedEvent] - Link ‘GF_Stue_TV-samsungtv📺be2f00b0_98d6_4ce1_b9d8_4280a6412249:power’ has been added.
2019-01-20 19:19:09.390 [.ItemChannelLinkAddedEvent] - Link ‘Varmepumpe_DeviceValues_LowPressostat-regoheatpump:serialHusdata:cecec0a8:deviceValues#lowPressostat’ has been added.
2019-01-20 19:19:09.401 [.ItemChannelLinkAddedEvent] - Link ‘Varmepumpe_ControlData_MaximalHotWater-regoheatpump:serialHusdata:cecec0a8:controlData#hotWaterOff’ has been added.
2019-01-20 19:19:09.408 [.ItemChannelLinkAddedEvent] - Link ‘GF_Redskapshus_Temperature-knx:device:bridge:generic:GF_Redskapshus_Temperature’ has been added.
2019-01-20 19:19:09.414 [.ItemChannelLinkAddedEvent] - Link ‘ColdFluidPump-regoheatpump:serialHusdata:8d9e73fd:deviceValues#coldFluidPump’ has been added.
2019-01-20 19:19:09.419 [.ItemChannelLinkAddedEvent] - Link ‘Stue_Bose_Power-bosesoundtouch:30:506583CE0123:power’ has been added.
2019-01-20 19:19:09.422 [.ItemChannelLinkAddedEvent] - Link ‘Varmepumpe_DeviceValues_HeatFluidPump-regoheatpump:serialHusdata:cecec0a8:deviceValues#heatFluidPump’ has been added.
2019-01-20 19:19:09.425 [.ItemChannelLinkAddedEvent] - Link ‘Varmepumpe_SensorValues_AirIntake-regoheatpump:serialHusdata:5a58bd01:sensorValues#airIntake’ has been added.
2019-01-20 19:19:09.429 [.ItemChannelLinkAddedEvent] - Link ‘Varmepumpe_SensorValues_RadiatorForward-regoheatpump:serialHusdata:cecec0a8:sensorValues#radiatorForward’ has been added.
2019-01-20 19:19:09.432 [.ItemChannelLinkAddedEvent] - Link ‘Varmepumpe_DeviceValues_SwitchValve-regoheatpump:serialHusdata:cecec0a8:deviceValues#switchValve’ has been added.
2019-01-20 19:19:09.434 [.ItemChannelLinkAddedEvent] - Link ‘Varmepumpe_SensorValues_HeatFluidIn-regoheatpump:serialHusdata:5a58bd01:sensorValues#heatFluidIn’ has been added.
2019-01-20 19:19:09.437 [.ItemChannelLinkAddedEvent] - Link ‘Varmepumpe_SensorValues_Compressor-regoheatpump:serialHusdata:cecec0a8:sensorValues#compressor’ has been added.
2019-01-20 19:19:09.440 [.ItemChannelLinkAddedEvent] - Link ‘Varmepumpe_SensorValues_RadiatorReturn-regoheatpump:serialHusdata:cecec0a8:sensorValues#radiatorReturn’ has been added.
2019-01-20 19:19:09.443 [.ItemChannelLinkAddedEvent] - Link ‘HusdataInterface_SensorValues_ColdFluidIn-regoheatpump:serialHusdata:8d9e73fd:sensorValues#coldFluidIn’ has been added.
2019-01-20 19:19:09.446 [.ItemChannelLinkAddedEvent] - Link ‘Varmepumpe_SensorValues_ColdFluidOut-regoheatpump:serialHusdata:cecec0a8:sensorValues#coldFluidOut’ has been added.
2019-01-20 19:19:09.450 [.ItemChannelLinkAddedEvent] - Link ‘Varmepumpe_SensorValues_Pool-regoheatpump:serialHusdata:cecec0a8:sensorValues#pool’ has been added.
2019-01-20 19:19:09.453 [.ItemChannelLinkAddedEvent] - Link ‘Varmepumpe_SensorValues_Outdoor-regoheatpump:serialHusdata:12eb66d3:sensorValues#outdoor’ has been added.
2019-01-20 19:19:09.456 [.ItemChannelLinkAddedEvent] - Link ‘Varmepumpe_ControlData_RadiatorForwardTarget-regoheatpump:serialHusdata:cecec0a8:controlData#radiatorForwardTarget’ has been added.
2019-01-20 19:19:09.459 [.ItemChannelLinkAddedEvent] - Link ‘ExternalHotWater-regoheatpump:serialHusdata:8d9e73fd:sensorValues#externalHotWater’ has been added.
2019-01-20 19:19:09.462 [.ItemChannelLinkAddedEvent] - Link ‘GF_Redskapshus_Port5_Lys-knx:device:bridge:generic:GF_Redskapshus_Port5_Light’ has been added.
2019-01-20 19:19:09.465 [.ItemChannelLinkAddedEvent] - Link ‘Varmepumpe_SensorValues_ColdFluidOut-regoheatpump:serialHusdata:5a58bd01:sensorValues#coldFluidOut’ has been added.
2019-01-20 19:19:09.468 [.ItemChannelLinkAddedEvent] - Link ‘Varmepumpe_DeviceValues_SwitchValve2-regoheatpump:serialHusdata:cecec0a8:deviceValues#switchValve2’ has been added.
2019-01-20 19:19:09.471 [.ItemChannelLinkAddedEvent] - Link ‘GF_Redskapshus_Port3_Lys-knx:device:bridge:generic:GF_Redskapshus_Port3_Light’ has been added.
2019-01-20 19:19:09.474 [.ItemChannelLinkAddedEvent] - Link ‘Varmepumpe_SensorValues_ColdFluidIn-regoheatpump:serialHusdata:cecec0a8:sensorValues#coldFluidIn’ has been added.
2019-01-20 19:19:09.477 [.ItemChannelLinkAddedEvent] - Link ‘Varmepumpe_SensorValues_AirIntake-regoheatpump:serialHusdata:cecec0a8:sensorValues#airIntake’ has been added.
2019-01-20 19:19:09.481 [.ItemChannelLinkAddedEvent] - Link ‘Varmepumpe_SensorValues_Compressor-regoheatpump:serialHusdata:12eb66d3:sensorValues#compressor’ has been added.
2019-01-20 19:19:09.484 [.ItemChannelLinkAddedEvent] - Link ‘Varmepumpe_ControlData_RadiatorReturnTarget-regoheatpump:serialHusdata:5a58bd01:controlData#radiatorReturnTarget’ has been added.
2019-01-20 19:19:09.486 [.ItemChannelLinkAddedEvent] - Link ‘Varmepumpe_SensorValues_HotWater-regoheatpump:serialHusdata:5a58bd01:sensorValues#hotWater’ has been added.
2019-01-20 19:19:09.489 [.ItemChannelLinkAddedEvent] - Link ‘Varmepumpe_ControlData_AdditionalHeatPower-regoheatpump:serialHusdata:5a58bd01:controlData#addHeatPowerPercent’ has been added.
2019-01-20 19:19:09.492 [.ItemChannelLinkAddedEvent] - Link ‘Varmepumpe_Settings_HeatCurve-regoheatpump:serialHusdata:cecec0a8:settings#heatCurve’ has been added.
2019-01-20 19:19:09.495 [.ItemChannelLinkAddedEvent] - Link ‘Varmepumpe_SensorValues_HeatFluidOut-regoheatpump:serialHusdata:5a58bd01:sensorValues#heatFluidOut’ has been added.
2019-01-20 19:19:09.498 [.ItemChannelLinkAddedEvent] - Link ‘AdditionalHeat3kW-regoheatpump:serialHusdata:8d9e73fd:deviceValues#additionalHeat3kW’ has been added.
2019-01-20 19:19:09.501 [.ItemChannelLinkAddedEvent] - Link ‘HusdataInterface_SensorValues_ColdFluidOut-regoheatpump:serialHusdata:8f170952:sensorValues#coldFluidOut’ has been added.
2019-01-20 19:19:09.504 [.ItemChannelLinkAddedEvent] - Link ‘Varmepumpe_ControlData_CompressorSpeed-regoheatpump:serialHusdata:cecec0a8:controlData#compressorSpeed’ has been added.
2019-01-20 19:19:09.506 [.ItemChannelLinkAddedEvent] - Link ‘Varmepumpe_Settings_IndoorTarget-regoheatpump:serialHusdata:cecec0a8:settings#indoorTempSetting’ has been added.
2019-01-20 19:19:09.509 [.ItemChannelLinkAddedEvent] - Link ‘VPVerksted_SensorValues_Outdoor-regoheatpump:serialHusdata:4f00fe28:sensorValues#outdoor’ has been added.
==> /var/log/openhab2/openhab.log <==
2019-01-20 19:19:11.421 [INFO ] [.dashboard.internal.DashboardService] - Started Dashboard at http://10.251.10.146:8080
2019-01-20 19:19:11.431 [INFO ] [.dashboard.internal.DashboardService] - Started Dashboard at https://10.251.10.146:8443
==> /var/log/openhab2/events.log <==
2019-01-20 19:19:13.753 [hingStatusInfoChangedEvent] - ‘bosesoundtouch:30:506583CE0123’ changed from UNINITIALIZED to INITIALIZING
2019-01-20 19:19:14.970 [hingStatusInfoChangedEvent] - ‘bosesoundtouch:30:506583CE0123’ changed from INITIALIZING to ONLINE
==> /var/log/openhab2/openhab.log <==
2019-01-20 19:19:15.015 [INFO ] [arthome.ui.paper.internal.PaperUIApp] - Started Paper UI at /paperui
==> /var/log/openhab2/events.log <==
2019-01-20 19:19:15.413 [vent.ItemStateChangedEvent] - Stue_Bose_Volume changed from NULL to 24
2019-01-20 19:19:15.727 [vent.ItemStateChangedEvent] - Stue_Bose_Power changed from NULL to OFF
==> /var/log/openhab2/openhab.log <==
2019-01-20 19:19:16.884 [INFO ] [b.core.service.AbstractActiveService] - HTTP Refresh Service has been started
==> /var/log/openhab2/events.log <==
2019-01-20 19:19:17.608 [hingStatusInfoChangedEvent] - ‘knx:ip:bridge’ changed from UNINITIALIZED to INITIALIZING
2019-01-20 19:19:17.838 [hingStatusInfoChangedEvent] - ‘knx:ip:bridge’ changed from INITIALIZING to UNKNOWN
2019-01-20 19:19:18.049 [hingStatusInfoChangedEvent] - ‘samsungtv📺be2f00b0_98d6_4ce1_b9d8_4280a6412249’ changed from UNINITIALIZED to INITIALIZING
2019-01-20 19:19:18.147 [hingStatusInfoChangedEvent] - ‘samsungtv📺be2f00b0_98d6_4ce1_b9d8_4280a6412249’ changed from INITIALIZING to OFFLINE
2019-01-20 19:19:18.239 [hingStatusInfoChangedEvent] - ‘samsungtv📺19cb6b46_4ad5_fe90_df8c_9b299727521a’ changed from UNINITIALIZED to INITIALIZING
2019-01-20 19:19:18.274 [vent.ItemStateChangedEvent] - GF_Stue_TV changed from NULL to OFF
2019-01-20 19:19:18.279 [hingStatusInfoChangedEvent] - ‘samsungtv📺19cb6b46_4ad5_fe90_df8c_9b299727521a’ changed from INITIALIZING to OFFLINE
2019-01-20 19:19:18.338 [hingStatusInfoChangedEvent] - ‘samsungtv📺be2f00b0_98d6_4ce1_b9d8_4280a6412249’ changed from OFFLINE to ONLINE
2019-01-20 19:19:18.379 [vent.ItemStateChangedEvent] - GF_Stue_TV changed from OFF to ON
2019-01-20 19:19:18.390 [vent.ItemStateChangedEvent] - GF_Redskapshus_TV changed from NULL to OFF
2019-01-20 19:19:18.554 [hingStatusInfoChangedEvent] - ‘knx:device:bridge:generic’ changed from UNINITIALIZED to INITIALIZING
2019-01-20 19:19:18.560 [hingStatusInfoChangedEvent] - ‘knx:device:bridge:generic’ changed from INITIALIZING to OFFLINE (BRIDGE_OFFLINE)
2019-01-20 19:19:18.709 [vent.ItemStateChangedEvent] - Volum changed from NULL to 0
2019-01-20 19:19:18.953 [hingStatusInfoChangedEvent] - ‘knx:ip:bridge’ changed from UNKNOWN to ONLINE
2019-01-20 19:19:18.968 [hingStatusInfoChangedEvent] - ‘knx:device:bridge:generic’ changed from OFFLINE (BRIDGE_OFFLINE) to UNKNOWN
2019-01-20 19:19:21.997 [vent.ItemStateChangedEvent] - GF_Redskapshus_Temperature changed from NULL to -5.6000000000000005
==> /var/log/openhab2/openhab.log <==
2019-01-20 19:19:22.146 [ERROR] [.iot.device.transport.IotHubSendTask] - IotHubSendTask constructor called with null value for parameter transport
2019-01-20 19:19:22.160 [ERROR] [t.device.transport.IotHubReceiveTask] - IotHubReceiveTask constructor called with null value for parameter transport
2019-01-20 19:19:22.660 [ERROR] [.iot.device.transport.IotHubSendTask] - IotHubSendTask constructor called with null value for parameter transport
2019-01-20 19:19:22.666 [ERROR] [t.device.transport.IotHubReceiveTask] - IotHubReceiveTask constructor called with null value for parameter transport
2019-01-20 19:19:23.479 [INFO ] [io.openhabcloud.internal.CloudClient] - Connected to the openHAB Cloud service (UUID = ce0927c8-6c0e-4ca6-bacd-24881a3f5413, base URL = http://localhost:8080)
==> /var/log/openhab2/events.log <==
2019-01-20 19:19:24.829 [vent.ItemStateChangedEvent] - Varmepumpe_SensorValues_ColdFluidOut changed from NULL to -0.1
2019-01-20 19:19:25.319 [vent.ItemStateChangedEvent] - Varmepumpe_DeviceValues_Fan changed from NULL to OFF
2019-01-20 19:19:25.371 [vent.ItemStateChangedEvent] - GF_Redskapshus_Port4_Lukke changed from NULL to OFF
2019-01-20 19:19:25.420 [vent.ItemStateChangedEvent] - Varmepumpe_SensorValues_AirIntake changed from NULL to -2.8
2019-01-20 19:19:25.474 [vent.ItemStateChangedEvent] - GF_Redskapshus_Light changed from NULL to OFF
2019-01-20 19:19:25.523 [vent.ItemStateChangedEvent] - GF_Redskapshus_Port5_Apne changed from NULL to OFF
2019-01-20 19:19:25.558 [vent.ItemStateChangedEvent] - Varmepumpe_ControlData_CompressorSpeed changed from NULL to 0.1
2019-01-20 19:19:25.599 [vent.ItemStateChangedEvent] - Varmepumpe_DeviceValues_HighPressostat changed from NULL to OFF
2019-01-20 19:19:26.139 [vent.ItemStateChangedEvent] - Varmepumpe_SensorValues_HeatFluidIn changed from NULL to 7.1
2019-01-20 19:19:26.224 [vent.ItemStateChangedEvent] - GF_Redskapshus_Verksted_Temperature changed from NULL to 8.48
2019-01-20 19:19:26.264 [vent.ItemStateChangedEvent] - Varmepumpe_DeviceValues_Compressor changed from NULL to OFF
2019-01-20 19:19:26.300 [vent.ItemStateChangedEvent] - TV changed from NULL to ON
2019-01-20 19:19:26.504 [vent.ItemStateChangedEvent] - Varmepumpe_SensorValues_ColdFluidIn changed from NULL to 8.0
2019-01-20 19:19:26.753 [vent.ItemStateChangedEvent] - Varmepumpe_SensorValues_Compressor changed from NULL to 2.1
2019-01-20 19:19:26.811 [vent.ItemStateChangedEvent] - Varmepumpe_SensorValues_Indoor changed from NULL to -52.1
2019-01-20 19:19:27.083 [vent.ItemStateChangedEvent] - GF_Verksted_Port_Apne changed from NULL to OFF
2019-01-20 19:19:27.149 [vent.ItemStateChangedEvent] - Home_Hjemme changed from NULL to OFF
2019-01-20 19:19:27.219 [vent.ItemStateChangedEvent] - Varmepumpe_DeviceValues_SwitchValve changed from NULL to ON
2019-01-20 19:19:27.312 [vent.ItemStateChangedEvent] - GF_Redskapshus_Port4_Apne changed from NULL to OFF
2019-01-20 19:19:27.352 [vent.ItemStateChangedEvent] - Varmepumpe_DeviceValues_CollectedPulsesMeter2 changed from NULL to 1.0
2019-01-20 19:19:27.391 [vent.ItemStateChangedEvent] - Varmepumpe_DeviceValues_CollectedPulsesMeter1 changed from NULL to 1.0
2019-01-20 19:19:27.458 [vent.ItemStateChangedEvent] - Varmepumpe_SensorValues_Pool changed from NULL to 0.1
==> /var/log/openhab2/openhab.log <==
2019-01-20 19:19:27.760 [WARN ] [me.core.internal.events.EventHandler] - Dispatching event to subscriber ‘org.openhab.io.internal.azureiothub.CloudService@1a20b2c’ takes more than 5000ms.
==> /var/log/openhab2/events.log <==
2019-01-20 19:19:27.879 [vent.ItemStateChangedEvent] - GF_Redskapshus_Port2_Lys changed from NULL to OFF
2019-01-20 19:19:27.926 [vent.ItemStateChangedEvent] - GF_Redskapshus_Port2_Apne changed from NULL to OFF
2019-01-20 19:19:27.964 [vent.ItemStateChangedEvent] - GF_Redskapshus_Port2_Lukke changed from NULL to OFF
2019-01-20 19:19:28.004 [vent.ItemStateChangedEvent] - Varmepumpe_DeviceValues_HeatFluidPump changed from NULL to ON
2019-01-20 19:19:28.041 [vent.ItemStateChangedEvent] - Home_Borte changed from NULL to OFF
2019-01-20 19:19:28.075 [vent.ItemStateChangedEvent] - Home_Natt changed from NULL to OFF
2019-01-20 19:19:28.236 [vent.ItemStateChangedEvent] - Varmepumpe_DeviceValues_ColdFluidPump changed from NULL to OFF
2019-01-20 19:19:28.290 [vent.ItemStateChangedEvent] - GF_Redskapshus_Port3_Lys changed from NULL to OFF
2019-01-20 19:19:28.341 [vent.ItemStateChangedEvent] - Varmepumpe_DeviceValues_RadiatorPump changed from NULL to ON
2019-01-20 19:19:28.386 [vent.ItemStateChangedEvent] - GF_Redskapshus_Port5_Lukke changed from NULL to OFF
2019-01-20 19:19:28.454 [vent.ItemStateChangedEvent] - HusdataInterface_SensorValues_RadiatorReturn changed from NULL to 7.5
2019-01-20 19:19:28.742 [vent.ItemStateChangedEvent] - Varmepumpe_DeviceValues_SwitchValve2 changed from NULL to ON
2019-01-20 19:19:28.913 [vent.ItemStateChangedEvent] - GF_Redskapshus_Port4_Lys changed from NULL to OFF
2019-01-20 19:19:28.965 [vent.ItemStateChangedEvent] - GF_Redskapshus_Port3_Apne changed from NULL to OFF
2019-01-20 19:19:29.002 [vent.ItemStateChangedEvent] - Varmepumpe_SensorValues_HeatFluidOut changed from NULL to 8.9
2019-01-20 19:19:29.056 [vent.ItemStateChangedEvent] - TVUE46D8000_Volume changed from NULL to 12.0
2019-01-20 19:19:29.158 [vent.ItemStateChangedEvent] - GF_Verksted_Port_Lukke changed from NULL to OFF
2019-01-20 19:19:29.196 [vent.ItemStateChangedEvent] - GF_Redskapshus_Port3_Lukke changed from NULL to OFF
2019-01-20 19:19:29.230 [vent.ItemStateChangedEvent] - Varmepumpe_SensorValues_Outdoor changed from NULL to -1.7
2019-01-20 19:19:29.277 [vent.ItemStateChangedEvent] - GF_Redskapshus_Port5_Lys changed from NULL to OFF
2019-01-20 19:19:29.385 [vent.ItemStateChangedEvent] - Varmepumpe_SensorValues_HotWater changed from NULL to 30.4
==> /var/log/openhab2/openhab.log <==
2019-01-20 19:19:30.888 [INFO ] [panel.internal.HABPanelDashboardTile] - Started HABPanel at /habpanel
2019-01-20 19:19:31.115 [INFO ] [ebuilder.internal.HomeBuilderServlet] - Started Home Builder at /homebuilder
==> /var/log/openhab2/events.log <==
2019-01-20 19:19:32.041 [hingStatusInfoChangedEvent] - ‘knx:device:bridge:generic’ changed from UNKNOWN to OFFLINE
==> /var/log/openhab2/openhab.log <==
2019-01-20 19:19:35.449 [WARN ] [org.apache.felix.fileinstall ] - Error while starting bundle: file:/usr/share/openhab2/addons/org.openhab.binding.regoheatpump-2.5.0-SNAPSHOT.jar
org.osgi.framework.BundleException: Could not resolve module: org.openhab.binding.regoheatpump [236]
Another singleton bundle selected: osgi.identity; type=“osgi.bundle”; version:Version=“2.5.0.201901142229”; osgi.identity=“org.openhab.binding.regoheatpump”; singleton:=“true”
2019-01-20 19:19:53.531 [ERROR] [core.karaf.internal.FeatureInstaller] - Failed installing ‘openhab-binding-knx1’
==> /var/log/openhab2/events.log <==
2019-01-20 19:20:12.533 [vent.ItemStateChangedEvent] - GF_Redskapshus_Verksted_Temperature changed from 8.48 to 8.49
==> /var/log/openhab2/openhab.log <==
2019-01-20 19:20:40.022 [ERROR] [core.karaf.internal.FeatureInstaller] - Failed installing ‘openhab-binding-knx1’
==> /var/log/openhab2/events.log <==
2019-01-20 19:20:54.970 [vent.ItemStateChangedEvent] - GF_Redskapshus_Verksted_Temperature changed from 8.49 to 8.5
==> /var/log/openhab2/openhab.log <==
2019-01-20 19:21:12.862 [WARN ] [nx.internal.client.AbstractKNXClient] - Giving up reading datapoint 1/0/8, the number of maximum retries (3) is reached.
==> /var/log/openhab2/events.log <==
2019-01-20 19:21:21.253 [vent.ItemStateChangedEvent] - GF_Redskapshus_Temperature changed from -5.6000000000000005 to -5.8
==> /var/log/openhab2/openhab.log <==
2019-01-20 19:21:22.927 [WARN ] [nx.internal.client.AbstractKNXClient] - Giving up reading datapoint 1/0/12, the number of maximum retries (3) is reached.
==> /var/log/openhab2/events.log <==
2019-01-20 19:21:27.666 [hingStatusInfoChangedEvent] - ‘regoheatpump:serialHusdata:8082cb0f’ changed from UNINITIALIZED to INITIALIZING
2019-01-20 19:21:27.719 [hingStatusInfoChangedEvent] - ‘regoheatpump:serialHusdata:8082cb0f’ changed from INITIALIZING to UNKNOWN
==> /var/log/openhab2/openhab.log <==
2019-01-20 19:21:30.419 [WARN ] [pump.internal.handler.HusdataHandler] - Processing request failed
java.io.IOException: Underlying input stream returned zero bytes
==> /var/log/openhab2/events.log <==
2019-01-20 19:21:30.795 [hingStatusInfoChangedEvent] - ‘regoheatpump:serialHusdata:8082cb0f’ changed from UNKNOWN to OFFLINE
==> /var/log/openhab2/openhab.log <==
2019-01-20 19:21:32.181 [WARN ] [pump.internal.handler.HusdataHandler] - Processing request failed
java.io.IOException: Underlying input stream returned zero bytes
2019-01-20 19:21:32.992 [WARN ] [nx.internal.client.AbstractKNXClient] - Giving up reading datapoint 1/0/16, the number of maximum retries (3) is reached.
2019-01-20 19:21:33.804 [WARN ] [pump.internal.handler.HusdataHandler] - Processing request failed
java.io.IOException: Underlying input stream returned zero bytes
2019-01-20 19:21:35.484 [WARN ] [pump.internal.handler.HusdataHandler] - Processing request failed
java.io.IOException: Underlying input stream returned zero bytes
2019-01-20 19:21:37.051 [WARN ] [pump.internal.handler.HusdataHandler] - Processing request failed
java.io.IOException: Underlying input stream returned zero bytes
2019-01-20 19:21:37.561 [ERROR] [core.karaf.internal.FeatureInstaller] - Failed installing ‘openhab-binding-knx1’
2019-01-20 19:21:38.670 [WARN ] [pump.internal.handler.HusdataHandler] - Processing request failed
java.io.IOException: Underlying input stream returned zero bytes
2019-01-20 19:21:40.295 [WARN ] [pump.internal.handler.HusdataHandler] - Processing request failed
java.io.IOException: Underlying input stream returned zero bytes
2019-01-20 19:21:41.920 [WARN ] [pump.internal.handler.HusdataHandler] - Processing request failed
java.io.IOException: Underlying input stream returned zero bytes
2019-01-20 19:21:43.056 [WARN ] [nx.internal.client.AbstractKNXClient] - Giving up reading datapoint 1/0/24, the number of maximum retries (3) is reached.
2019-01-20 19:21:43.540 [WARN ] [pump.internal.handler.HusdataHandler] - Processing request failed
java.io.IOException: Underlying input stream returned zero bytes
2019-01-20 19:21:45.160 [WARN ] [pump.internal.handler.HusdataHandler] - Processing request failed
java.io.IOException: Underlying input stream returned zero bytes