Reconfig failes for Innr SP120 power plug

See original GitHub issue

Describe the bug After installing the latest core-2021.12.1 there was a quirk added for the Innr SP120 plug. I guess this is the quirk: Innr SP120 multiplier fix #1174 A fix I’m really looking forward too!!! But I don’t observe that the values where corrected, So I initiated a reconfigure in ZHA (using a Conbee 2 stick). The reconfigure process fails (see below) and the values remain wrong!

To Reproduce

  • press reconfigure for the SP120 device in ZHA

Expected behavior I expect the reconfigure succeeds and that the the values from then on get corrected by the new multipliers

Screenshots The result of reconfigure: Capture

Additional context The device info: Capture2

The device signature:

{
  "node_descriptor": "NodeDescriptor(logical_type=<LogicalType.Router: 1>, complex_descriptor_available=0, user_descriptor_available=0, reserved=0, aps_flags=0, frequency_band=<FrequencyBand.Freq2400MHz: 8>, mac_capability_flags=<MACCapabilityFlags.AllocateAddress|RxOnWhenIdle|MainsPowered|FullFunctionDevice: 142>, manufacturer_code=4454, maximum_buffer_size=127, maximum_incoming_transfer_size=80, server_mask=0, maximum_outgoing_transfer_size=80, descriptor_capability_field=<DescriptorCapability.NONE: 0>, *allocate_address=True, *is_alternate_pan_coordinator=False, *is_coordinator=False, *is_end_device=False, *is_full_function_device=True, *is_mains_powered=True, *is_receiver_on_when_idle=True, *is_router=True, *is_security_capable=False)",
  "endpoints": {
    "1": {
      "profile_id": 49246,
      "device_type": "0x0010",
      "in_clusters": [
        "0x0000",
        "0x0003",
        "0x0004",
        "0x0005",
        "0x0006",
        "0x0008",
        "0x000a",
        "0x0702",
        "0x0b04"
      ],
      "out_clusters": [
        "0x0003",
        "0x000a",
        "0x0019"
      ]
    },
    "2": {
      "profile_id": 49246,
      "device_type": "0x1000",
      "in_clusters": [
        "0x1000"
      ],
      "out_clusters": []
    }
  },
  "manufacturer": "innr",
  "model": "SP 120",
  "class": "zhaquirks.innr.innr_sp120_plug.SP120"
}

Issue Analytics

  • State:closed
  • Created 2 years ago
  • Comments:21 (10 by maintainers)

github_iconTop GitHub Comments

1reaction
Adminiugacommented, Dec 15, 2021

nah, it does look right. just the AC_POWER_DIVISOR reads as 10, that’s why it’s 0.4W

1reaction
dmulcaheycommented, Dec 15, 2021

I see some unsupported attributes responses… those should be no big deal. there is one interesting response that I have to look at: ConfigureReportingResponseRecord(status=141, direction=0, attrid=0) not sure how this response code makes sense tbh. INVALID_DATA_TYPE = 0x8D

@Adminiuga have you ever seen this come back in this response before?

Read more comments on GitHub >

github_iconTop Results From Across the Web

How to Reset your Innr Smart Plugs - YouTube
This video will explain the reset method for Innr Smart Plugs. This reset method is the same for EU Smart Plugs, UK Smart...
Read more >
Service & Support with Video Tutorials, Q&A and Downloads
Getting started or need help with Innr Lighting products? Watch a video tutorial, download a manual or find out about some tips and...
Read more >
Philips Hue: Supported lights and devices [Hue compatible ...
The full power of iConnectHue will be unleashed when you use switches and sensors. ... Innr plug SP 120 (Euro plug) / SP...
Read more >
INNR Zigbee - main discussion topic - Page 2
March 2018 edited March 2018. The error looks like a general zigbee error: ... Does the new innr plug SP120 have power/energy metering?...
Read more >
SP 120 smart plug - deCONZ REST-API
Timestamp of the last power-cyle or rejoin. R. lastseen, ISO 8601 timestamp, Timestamp of the last communication. R. manufacturername, String, "innr", R.
Read more >

github_iconTop Related Medium Post

No results found

github_iconTop Related StackOverflow Question

No results found

github_iconTroubleshoot Live Code

Lightrun enables developers to add logs, metrics and snapshots to live code - no restarts or redeploys required.
Start Free

github_iconTop Related Reddit Thread

No results found

github_iconTop Related Hackernoon Post

No results found

github_iconTop Related Tweet

No results found

github_iconTop Related Dev.to Post

No results found

github_iconTop Related Hashnode Post

No results found